PRE_TERM – Pre-Charge and Termination Programmable Threshold
Pre-Term is used to program both the pre-charge current and the termination current threshold, on the
bq24050/2/5. The pre-charge current level is a factor of two higher than the termination current level. The
termination can be set between 5 and 50% of the programmed output current level set by ISET. If left floating the
termination and pre-charge are set internally at 10/20% respectively. The pre-charge-to-fast-charge, V
lowv
threshold is set to 2.5V.
R
PRE-TERM
= %Term × K
TERM
= %Pre-CHG × K
PRE-CHG
(0)
Where:
%Term is the percent of fast charge current where termination occurs;
%Pre-CHG is the percent of fast charge current that is desired during precharge;
K
TERM
and KPRE-CHG are gain factors found in the electrical specifications.