Datasheet
www.ti.com
TYPICAL OPERATING PERFORMANCE
V
IN
V
OUT
I
OUT
V
IN
V
OUT
FAULT
V
IN
V
OUT
FAULT
MaxV =6.84V
OUT
V
IN
V
OUT
MaxV =6.76V
OUT
FAULT
V
IN
V
OUT
MaxV =6.84V
OUT
FAULT
V
IN
V
OUT
MaxV =6.76V
OUT
FAULT
bq24314
bq24316
SLUS763C – JULY 2007 – REVISED OCTOBER 2007
Test conditions (unless otherwise noted) for typical operating performance: V
IN
= 5 V, C
IN
= 1 μ F, C
OUT
= 1 μ F,
R
ILIM
= 25 k Ω , R
BAT
= 100 k Ω , T
A
= 25 ° C, V
PU
= 3.3V (see Figure 23 for the Typical Application Circuit)
Figure 2. Normal Power-On Showing Soft-Start, Figure 3. OVP at Power-On, V
IN
= 0V to 9V, t
r
= 50 μ s
R
OUT
= 6.6 Ω
Figure 4. bq24316 OVP Response for Input Step, V
IN
= 5V Figure 5. bq24316 OVP Response for Input Step, V
IN
= 5V
to 12V, t
r
= 1 μ s to 12V, t
r
= 20 μ s
Figure 6. bq24314 OVP Response for Input Step, V
IN
= 5V Figure 7. bq24314 OVP Response for Input Step, V
IN
= 5V
to 12V, t
r
= 1 μ s to 12V, t
r
= 20 μ s
6 Submit Documentation Feedback Copyright © 2007, Texas Instruments Incorporated
Product Folder Link(s): bq24314 bq24316