Datasheet
Table Of Contents
- FEATURES
- APPLICATIONS
- DESCRIPTION
- TYPICAL APPLICATION
- ABSOLUTE MAXIMUM RATINGS
- RECOMMENDED OPERATING CONDITIONS
- DISSIPATION RATINGS
- ELECTRICAL CHARACTERISTICS
- TYPICAL OPERATING CHARACTERISTICS
- DEVICE INFORMATION
- FUNCTIONAL DESCRIPTIONS
- BATTERY CHARGER
- Autononous Power Source Selection
- Battery Pre-Conditioning
- Battery Charge Current
- Battery Voltage Regulation
- Charge Taper Detection, Termination and Regharge
- Sleep Mode for Charger
- Operation Modes
- Status Outputs
- PG Output (Power Good)
- CE Input (Charge Enable)
- Thermal Shutdown and Protection
- TImer Fault Recovery
- DC-DC CONVERTER
- BATTERY CHARGER
- APPLICATION INFORMATION
- ADJUSTABLE OUTPUT VOLTAGE VERSION (bq25015)
- FIXED OUTPUT VOLTAGE VERSION (bq25017)
- INPUT CAPACITOR SELECTION
- CHARGER OUTPUT CAPACITOR (DC-DC CONVERTER INPUT CAPACITOR) SELECTION
- DC-DC CONVERTER OUTPUT CAPACITOR SELECTION
- DC-DC CONVERTER OUTPUT INDUCTOR SELECTION
- CHARGING WHILE UNDER LOAD
- THERMAL CONSIDERATIONS
- PCB LAYOUT CONSIDERATIONS

www.ti.com
Vcc > V
I(BAT)
checked at all times
V
I(BAT)
<V
(LOWV)
Yes
No
t
(PRECHG)
Expired?
No
Yes
Indicate Fault
Yes
No
Yes
t
(CHG)
Expired?
No
Indicate Charge−
In−Progress
Regulate
I
O(PRECHG)
Indicate Charge−
In−Progress
Regulate Current
or Voltage
No
Reset and Start
t
(PRECHG)
timer
POR
Yes
Reset all timers,
Start t
(CHG)
timer
I
(TERM)
detection?
No
Yes
V
I(BAT)
< V
(RCH)
?
No
V
I(BAT)
<V
(LOWV)
No
Fault Condition
Yes
Yes
Indicate DONE
Turn off charge
Indicate SLEEP
MODE
SLEEP MODE
V
I(BAT)
<V
(LOWV)
Tj < T
(SHTDWN)
Tj < T
(SHTDWN)
Suspend charge
No
No
Yes
Indicate CHARGE
SUSPEND
I
(TAPER)
detection?
t
(TAPER)
Expired?
No
No
Yes
Yes
No
V
I(BAT)
> V
(RCH)
?
Enable I
(FAULT)
current
V
I(BAT)
> V
(RCH)
?
No
Yes
Yes
Disable I
(FAULT)
current
Yes
bq25015
bq25017
SLUS721A – DECEMBER 2006 – REVISED MARCH 2007
FUNCTIONAL DESCRIPTIONS (continued)
Figure 14. Operational Flow Chart
11