8.3 CC Offset Calibration
Select the Current tab. CC Offset Calibration performs the internal calibration of the coulomb counter
input offset.
8.4 Board Offset Calibration
This performs the offset calibration for the current offset of the board. It is expected that no current is
flowing through the sense resistor while performing this calibration step. Remove load/external voltage
and short Pack– to Batt–.
Click the Calibrate Board Offset button.
8.5 Pack Current Calibration
Connect a load to Pack+/Load+ and Pack–/Load– that draws approximately 2 A. Measure the current and
type the value into Enter Actual Current using (–) for current in discharge direction.
Click the Calibrate Pack Current button.
Figure 10. Current Calibration Screen
9 Pro (Advanced) Screen
9.1 SMB Communication
The set of read/write operations over the SMBus are not specific to any gas gauge. These are provided as
general-purpose communication tools (Figure 12).