I
2
C Pro (Advanced) Screen
3. Send command 0x0f00 to MAC (0x00) using SMBus Pro screen on EVSW.
4. Disconnect J1 from the SMBus connector of the EV2300/EV2400, and connect to the I
2
C connector of
EV2300/EV2400.
5. Click on the I
2
C Pro button on the EVSW to change to the I
2
C Pro screen.
6. Using the browse function, select the firmware for programming.
7. Click on the Program button to program the firmware.
8. Click Execute Program on 8032 on I
2
C Pro to bring the gauge to firmware mode.
9. Disconnect J1 from the I
2
C connector of the EV2300/EV2400 interface board, and connect to the
SMBus connector of the EV2300/EV2400.
10. Click on the SBS tab to monitor the device. The device is now running in firmware mode.