Datasheet
bq29330
SLUS673E –SEPTEMBER 2005–REVISED MARCH 2012
www.ti.com
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted)
(1) (2)
bq29330 UNIT
Supply voltage range (VCC, BAT) –0.3 to 34
(VC1, VC2, VC3, VC4, PACK, PMS) –0.3 to 34
(VC5) –0.3 to 1.0
(SRP, SRN) –1.0 to 1.0
Input voltage range
(VC1 to VC2, VC2 to VC3, VC3 to VC4, VC4 –0.3 to 8.5
to VC5)
(WDI, SCLK, SDATA) –0.3 to 8.5 V
(DSG,CHG) –0.3 to BAT
(ZVCHG) –0.3 to 34
(GPOD) –0.3 to 34
Output voltage range
(TOUT, SDATA, CELL, XALERT, XRST, –0.3 to 7
LEDOUT)
(CELL+) –0.3 to 7
Current for cell balancing 10 mA
Storage temperature range, T
stg
–65 to 150 °C
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages are with respect to ground of this device except VCn–VC(n+1), where n=1, 2, 3, 4 cell voltage.
RECOMMENDED OPERATING CONDITIONS
MIN NOM MAX UNIT
Supply voltage ( VCC, BAT) 4.5 25 V
V
I(STARTUP)
Start up voltage (VCC, BAT) 5.5 V
VC1, VC2, VC3, VC4 0 VDD
VC5 0 0.5
V
I
Input voltage range SRP, SRN –0.5 0.5 V
VCn – VC(n+1), (n=1, 2, 3, 4 ) 0 5.0
PACK, PMS 25
V
IH
0.8×REG REG
Logic level input voltage SCLK, SDATA, WDI V
V
IL
0 0.2×REG
V
O
Output voltage GPOD 25 V
XALERT, SDATA, XRST REG
V
O
Output voltage range V
CELL+, CELL– 0.975
External 2.5-V REG capacitor C
REG
1.0 μF
External LEDOUT capacitor C
LED
2.2 μF
Extend CELL output capacitor C
CELL
0.1 μF
IOL GPOD 1 mA
RPACK 1 kΩ
Input frequency WDI 32.768 kHz
WDI high time 2 μs
Operating temperature –25 85 °C
T
A
Functional temperature –40 110 °C
6 Submit Documentation Feedback Copyright © 2005–2012, Texas Instruments Incorporated
Product Folder Link(s): bq29330