BATTERY PROTECTION DELAY TIMES
Typical values stated where T
A
= 25°C and BAT = 20 V, Min/Max values stated where T
A
= 40˚C to 105°C and BAT = 7.2 V
to 27 V (unless otherwise noted)
PARAMETER TEST CONDITION MIN NOM MAX UNIT
t
OV
OV detection delay-time range 0 3200 ms
COVT [µs/ms] = 0 100 µs
Δt
OV
OV detection delay-time step
COVT [µs/ms] = 1 100 ms
t
UV
UV detection delay-time range 0 3200 ms
CUVT[7] (µs/ms) = 0 100 µs
Δt
UV
UV detection delay-time step
CUVT[7] (µs/ms) = 1 100 ms
t
OT
OT detection delay-time range 0 2550 ms
Δt
OT
OT detection delay-ime step 10 ms
OV, UV, and OT detection delay-time
t
acr
CUVT, (COVT) 500 µs 12% 0% 10%
accuracy
(1)
V
OT
or V
OV
or V
UV
threshold exceeded by
t
(DETECT)
Protection comparator detection time 100 µs
10 mV
(1) Under double or multiple fault conditions (of a single type), the second or greater fault may have its delay time shortened by up to the
step time for the fault. I.e., the second and subsequent COV faults occurring within the delay time period for the first fault may have their
delay time shortened by up to 100 µs.
OTP EPROM PROGRAMMING CHARACTERISTICS
Typical values stated where T
A
= 25°C and BAT = 20 V, Min/Max values stated where T
A
= 40˚C to 105°C and BAT = 7.2 V
to 27 V (unless otherwise noted)
PARAMETER TEST CONDITION MIN NOM MAX UNIT
V
PROG
Programming voltage 6.75 7 7.25 V
t
PROG
Programming time V
BAT
20 V 50 ms
I
PROG
Programming current 10 20 mA
12 Copyright © 2011, Texas Instruments Incorporated