18
CC3135MOD
SWRS225A FEBRUARY 2019REVISED AUGUST 2019
www.ti.com
Submit Documentation Feedback
Product Folder Links: CC3135MOD
Specifications Copyright © 2019, Texas Instruments Incorporated
(1) TX power level = 0 implies maximum power (see Figure 5-1, Figure 5-2, and Figure 5-3). TX power level = 4 implies output power
backed off approximately 4 dB.
(2) The CC3135MOD system is a constant power-source system. The active current numbers scale based on the V
BAT
voltage supplied.
(3) The RX current is measured with a 1-Mbps throughput rate.
(4) DTIM = 1
(5) The complete calibration can take up to 17 mJ of energy from the battery over a time of 24 ms. In default mode, calibration is performed
sparingly, and typically occurs when re-enabling the NWP and when the temperature has changed by more than 20°C. There are two
additional calibration modes that may be used to reduced or completely eliminate the calibration event. For further details, see CC31XX
CC32XX SimpleLink™ Wi-Fi
®
and IoT Network Processor Programmer's Guide.
5.4 Current Consumption Summary: 2.4 GHz RF Band
T
A
= 25°C, V
BAT
= 3.6 V
PARAMETER TEST CONDITIONS
(1) (2)
MIN TYP MAX UNIT
TX
1 DSSS
TX power level = 0 272
mA
TX power level = 4 188
6 OFDM
TX power level = 0 248
TX power level = 4 179
54 OFDM
TX power level = 0 223
TX power level = 4 160
RX
(3)
1 DSSS 53
mA
54 OFDM 53
Idle connected
(4)
690 µA
LPDS 115 µA
Hibernate 5.5 µA
Shutdown 1 µA
Peak calibration current
(5)(3)
V
BAT
= 3.6 V 420
mAV
BAT
= 3.3 V 450
V
BAT
= 2.3 V 610
(1) TX power level = 0 implies maximum power (see Figure 5-1, Figure 5-2, and Figure 5-3). TX power level = 4 implies output power
backed off approximately 4 dB.
(2) The CC3135MOD system is a constant power-source system. The active current numbers scale based on the V
BAT
voltage supplied.
(3) The RX current is measured with a 1-Mbps throughput rate.
(4) DTIM = 1
(5) The complete calibration can take up to 17 mJ of energy from the battery over a time of 24 ms. In default mode, calibration is performed
sparingly, and typically occurs when re-enabling the NWP and when the temperature has changed by more than 20°C. There are two
additional calibration modes that may be used to reduced or completely eliminate the calibration event. For further details, see CC31XX,
CC32XX SimpleLink™ Wi-Fi
®
and IoT Network Processor Programmer's Guide.
5.5 Current Consumption Summary: 5 GHz RF Band
T
A
= 25°C, V
BAT
= 3.6 V
PARAMETER TEST CONDITIONS
(1) (2)
MIN TYP MAX UNIT
TX
6 OFDM 318
mA
54 OFDM 293
RX
(3)
54 OFDM 61 mA
Idle connected
(4)
690 µA
LPDS 115 µA
Hibernate 5.5 µA
Shutdown 1 µA
Peak calibration current
(5)(3)
V
BAT
= 3.6 V 290
mA
V
BAT
= 3.3 V 310
V
BAT
= 2.7 V 310
V
BAT
= 2.3 V 365