Data Sheet

Table Of Contents
TI Confidential NDA Restrictions
ADVANCEINFORMATION
POWER
OFF
HW INIT FW INIT
Device ready to
serve API calls
VBAT
nRESET
STATE
32-kHz
XTAL
T1
T2
T3
nHIB
RESET
27
CC3135MOD
www.ti.com
SWRS225A FEBRUARY 2019REVISED AUGUST 2019
Submit Documentation Feedback
Product Folder Links: CC3135MOD
SpecificationsCopyright © 2019, Texas Instruments Incorporated
5.15 Timing and Switching Characteristics
5.15.1 Power-Up Sequencing
For proper start-up of the CC3135MOD module, perform the recommended power-up sequencing as
follows:
1. Tie V
BAT1
(pin 37) and V
BAT2
(pin 40) together on the board.
2. Hold the nRESET pin low while the supplies are ramping up.
Figure 5-6 shows the reset timing diagram for the first-time power-up and reset removal.
Figure 5-6. First-Time Power-Up and Reset Removal Timing Diagram
Table 5-7 describes the timing requirements for the first-time power-up and reset removal.
Table 5-7. First-Time Power-Up and Reset Removal Timing Requirements
ITEM NAME DESCRIPTION MIN TYP MAX UNIT
T1 nReset time
nReset timing after VBAT supplies
are stable
1 ms
T2 Hardware wake-up time 25 ms
T3 Initialization time
Internal 32-kHz XTAL settling plus
firmware initialization time plus
radio calibration
1.35 s
5.15.2 Power-Down Sequencing
For proper power down of the CC3135MOD module, ensure that the nRESET (pin 35) and nHIB (pin 4)
pins have remained in a known state for a minimum of 200 ms before removing power from the module.
5.15.3 Device Reset
When a device restart is required, the user may issue a negative pulse on either the nHIB pin (pin 4) or on
the nRESET pin (pin 35), keeping the other pulled high, depending on the configuration of the platform. If
the nRESET pin is used, the user must insure the following:
A high-to-low reset pulse (on pin 35) of at least 200-ms duration
To ensure a proper reset sequence, the user must call the sl_stop function prior to toggling the reset.