User's Guide

Table Of Contents
TI Confidential NDA Restrictions
Hardware
www.ti.com
24
SWRU548AFebruary 2019
Submit Documentation Feedback
Copyright © 2019, Texas Instruments Incorporated
CC3235MODSF LaunchPad™ Development Kit (LAUNCHCC3235MOD)
Table 2. External Supply Connections and Enable Jumpers (continued)
Reference Use Comments
J26 LED EN If uninstalled, the LEDs connected to the GPIO are disabled; this can be used
to enable low-power measurements.
2.2.8 Reset Pullup Jumper
Table 3 lists the reset pullup jumper.
Table 3. Reset Pullup Jumper
Reference Use Comments
J13 RESET pullup Install this jumper to enable the pullup resistor on the nRESET pin of the
device, when the board is powered from an external supply.
2.2.9 Clocking
All of the required clocks are inside the module. There is no need to supply any external clock.