Timer_B Operation
13-7Timer_B
Continuous Mode
In continuous mode the timer repeatedly counts up to TBR
(max)
and restarts
from zero as shown in Figure 134. The compare latch TBCL0 works the same
way as the other capture/compare registers.
Figure 134. Continuous Mode
0h
TBR
(max)
The TBIFG interrupt flag is set when the timer counts from TBR
(max)
to zero.
Figure 135 shows the flag set cycle.
Figure 135. Continuous Mode Flag Setting
TBR
(max)
1 TBR
(max)
0h
Timer Clock
Timer
Set TBIFG
1h TBR
(max)
0hTBR
(max)
1