User manual

LCD_A Controller Operation
19-26 LCD_A Controller
LCDAVCTL1, LCD_A Voltage Control Register 1
76543210
Unused VLCDx Unused
rw0 rw0 rw0 rw0 rw0 rw0 rw0 rw0
Unused
Bits
75
Unused
VLCDx
Bits
41
Charge pump voltage select. LCDCPEN must be 1 for the charge pump to
be enabled. AV
CC
is used for V
LCD
when VLCDx = 0000 and VREFx = 00
and VLCDEXT = 0.
0000 Charge pump disabled.
0001 V
LCD
= 2.60V
0010 V
LCD
= 2.66V
0011 V
LCD
= 2.72V
0100 V
LCD
= 2.78V
0101 V
LCD
= 2.84V
0110 V
LCD
= 2.90V
0111 V
LCD
= 2.96V
1000 V
LCD
= 3.02V
1001 V
LCD
= 3.08V
1010 V
LCD
= 3.14V
1011 V
LCD
= 3.20V
1100 V
LCD
= 3.26V
1101 V
LCD
= 3.32V
1110 V
LCD
= 3.38V
1111 V
LCD
= 3.44V
Unused
Bit 0 Unused