Datasheet

7.0 DC and AC Specifications (Continued)
101 www.national.com
DP83815
7.2.7 EEPROM Auto-Load
Number Parameter Min Max Units
7.2.7.1
EECLK Cycle Time 4 us
7.2.7.2
EECLK Delay from EESEL Valid 1 us
7.2.7.3
EECLK Low to EESEL Invalid 2 us
7.2.7.4
EECLK to EEDO Valid 2 us
7.2.7.5
EEDI Setup Time to EECLK 2 us
7.2.7.6
EEDI Hold Time from EECLK 2 us
Refer to FM93C46 data sheet
T1T1
T2
T5
T6
T3
T4
EECLK
EESEL
EEDO
EEDI