Datasheet
DRV134, DRV135
6
SBOS094A
www.ti.com
TYPICAL PERFORMANCE CURVES (Cont.)
At T
A
= +25°C, V
S
= ±18V, R
L
= 600Ω differential connected between +V
O
and –V
O
, unless otherwise noted.
OUTPUT VOLTAGE SWING
vs OUTPUT CURRENT
Output Current (mA)
Output Voltage Swing (V)
0 ±20 ±40 ±60 ±80 ±100
18
16
14
12
10
8
–8
–10
–12
–14
–16
–18
–55°C
+25°C
+125°C
+125°C
+25°C –55°C
SHORT-CIRCUIT CURRENT vs TEMPERATURE
Temperature (°C)
Short-Circuit Current (mA)
–75 –50 –25 0 25 50 75 125100
±120
±100
±80
±60
±40
±20
+I
SC
–I
SC
DIFFERENTIAL OFFSET VOLTAGE
PRODUCTION DISTRIBUTION
Percent of Units (%)
Differential Offset Voltage (mV)
–10
–9
–8
–7
–6
–5
–4
–3
–2
–1
0
1
2
3
4
5
6
7
8
9
10
45
40
35
30
25
20
15
10
5
0
Typical production
distribution of packaged
units. All package types
included.
COMMON-MODE OFFSET VOLTAGE
PRODUCTION DISTRIBUTION
Percent of Units (%)
Common-Mode Offset Voltage (mV)
–250
–225
–200
–175
–150
–125
–100
–75
–50
–25
0
25
50
75
100
125
150
175
200
225
250
35
30
25
20
15
10
5
0
Typical production
distribution of packaged
units. All package types
included.
OUTPUT VOLTAGE SWING
vs SUPPLY VOLTAGE
Supply Voltage (V)
Differential Output Voltage (Vrms)
±4 ±6
THD+N ≤ 0.1%
±8 ±10 ±12 ±14 ±16 ±18
20
16
12
8
4
0
THD+N ≤ 0.1%
QUIESCENT CURRENT
vs SUPPLY VOLTAGE
Supply Voltage (V)
Quiescent Current (mA)
±4 ±18±16±14±12±10±8±6
±5.6
±5.4
±5.2
±5
±4.8
±4.6
T = –55°C
T = +25°C
T = +125°C