ABSOLUTE MAXIMUM RATINGS
(1)
Supply Voltage +7V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Signal Input Terminals:
Voltage
(2)
−0.5V to V
DD
+ 0.5V. . . . . . . . . . . . . . . . . . . . . . . . . . .
Differential Amplifier
(3)
−10V to +10V. . . . . . . . . . . . . . . . . . . . . .
Current at IS1 and IS2 ±75mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Current (pins other than IS1 and IS2)
(2)
±25mA. . . . . . . . . . . . . .
I
COMP
Short Circuit
(4)
+250mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating Junction Temperature −50°C to +150°C. . . . . . . . . . . . .
Storage Temperature −55°C to +150°C. . . . . . . . . . . . . . . . . . . . . . .
ESD Rating:
Human Body Model (HBM)
Pins IA
IN1
and IA
IN2
Only 1kV. . . . . . . . . . . . . . . . . . . . . . . . . . .
All Other Pins 4kV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(1)
Stresses above these ratings may cause permanent damage.
Exposure to absolute maximum conditions for extended periods
may degrade device reliability. These are stress ratings only, and
functional operation of the device at these or any other conditions
beyond those specified is not supported.
(2)
Input terminals are diode-clamped to the power-supply rails.
Input signals that can swing more than 0.5V beyond the supply
rails must be current limited, except for the differential amplifier
input pins.
(3)
These inputs are not internally protected against over voltage.
The differential amplifier input pins must be limited to 5mA, max or
±10V, max.
(4)
Power-limited; observe maximum junction temperature.
This integrated circuit can be damaged by ESD. Texas
Instruments recommends that all integrated circuits be
handled with appropriate precautions. Failure to observe
proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to
complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could
cause the device not to meet its published specifications.
ORDERING INFORMATION
(1)
PRODUCT PACKAGE-LEAD
PACKAGE
DESIGNATOR
PACKAGE
MARKING
DRV401
QFN-20
(5mm x 5mm)
RGW HAAQ
DRV401 SO-20 DWP DRV401A
(1)
For the most current package and ordering information see the
Package Option Addendum at the end of this document, or see
the TI web site at www.ti.com.