Datasheet

33.3kW
33.3kW
Æ1 Æ2 Æ2 Æ1
Æ2Æ2
Zer -
Drift
Æ
Æ1 Æ1
OUT
REF2
REF1
GND
V+
V+
+IN -IN
See Note (1)
PRODUCTGAIN
50V/V
100V/V INA286
200V/V INA283
500V/V INA284
1000V/V INA285
INA282
INA282, INA283
INA284, INA285
INA286
SBOS485B NOVEMBER 2009REVISED SEPTEMBER 2012
www.ti.com
REFERENCE PIN CONNECTION OPTIONS
Figure 33 illustrates a test circuit for reference divider accuracy. The output of the INA282 family can be
connected for unidirectional or bidirectional operation. Note that neither the REF1 pin nor the REF2 pin may be
connected to any voltage source lower than GND or higher than V+, and that the effective reference voltage
(REF1 + REF2)/2 must be 9V or less. This parameter means that the V+ reference output connection shown in
Figure 35 is not allowed for V+ greater than 9V. However, the split-supply reference connection shown in
Figure 37 is allowed for all values of V+ up to 18V.
(1) Reference divider accuracy is determined by measuring the output with the reference voltage applied to alternate reference resistors, and
calculating a result such that the amplifier offset is cancelled in the final measurement.
Figure 33. Test Circuit for Reference Divider Accuracy
14 Submit Documentation Feedback Copyright © 2009–2012, Texas Instruments Incorporated
Product Folder Links: INA282 INA283 INA284 INA285 INA286