Datasheet

LM4040x41I Electrical Characteristics
DV
Z
DI
Z
LM4040
SLOS456K JANUARY 2005 REVISED MARCH 2008 ..................................................................................................................................................
www.ti.com
at industrial temperature range, full-range T
A
= 40 ° C to 85 ° C (unless otherwise noted)
LM4040C41I LM4040D41I
PARAMETER TEST CONDITIONS T
A
UNIT
MIN TYP MAX MIN TYP MAX
V
Z
Reverse breakdown voltage I
Z
= 100 μ A 25 ° C 4.096 4.096 V
25 ° C 20 20 41 41
Reverse breakdown voltage
Δ V
Z
I
Z
= 100 μ A mV
tolerance
Full range 47 47 81 81
25 ° C 50 83 50 83
I
Z,min
Minimum cathode current μ A
Full range 88 88
I
Z
= 10 mA 25 ° C ± 30 ± 30
25 ° C ± 20 ± 20
Average temperature coefficient
α
VZ
I
Z
= 1 mA ppm/ ° C
of reverse breakdown voltage
Full range ± 100 ± 150
I
Z
= 100 μ A 25 ° C ± 20 ± 20
25 ° C 0.5 0.9 0.5 1.2
I
Z,min
< I
Z
< 1 mA
Reverse breakdown voltage
Full range 1.2 1.5
change with cathode current mV
25 ° C 3 7 3 9
change
1 mA < I
Z
< 15 mA
Full range 10 13
I
Z
= 1 mA, f = 120 Hz,
Z
Z
Reverse dynamic impedance 25 ° C 0.5 1 0.5 1.3
I
AC
= 0.1 I
Z
I
Z
= 100 μ A,
e
N
Wideband noise 25 ° C 80 80 μ V
RMS
10 Hz f 10 kHz
t = 1000 h,
Long-term stability of reverse
T
A
= 25 ° C ± 0.1 ° C, 120 120 ppm
breakdown voltage
I
Z
= 100 μ A
V
HYST
Thermal hysteresis
(1)
Δ T
A
= 40 ° C to 125 ° C 0.08 0.08 %
(1) Thermal hysteresis is defined as V
Z,25 ° C
(after cycling to 40 ° C) V
Z,25 ° C
(after cycling to 125 ° C).
18 Submit Documentation Feedback Copyright © 2005 2008, Texas Instruments Incorporated