Datasheet

LM4132
V
IN
Input
5V
Output
2.5V
V
REF
EN
GND
Enable
C
IN
C
OUT
*
*
LM4132
www.ti.com
SNVS372C AUGUST 2005REVISED APRIL 2013
LM4132 SOT-23 Precision Low Dropout Voltage Reference
Check for Samples: LM4132
1
FEATURES
DESCRIPTION
The LM4132 family of precision voltage references
2
Output Initial Voltage Accuracy 0.05%
performs comparable to the best laser-trimmed
Low Temperature Coefficient 10ppm/°C
bipolar references, but in cost effective CMOS
Low Supply Current, 60µA
technology. The key to this break through is the use
of EEPROM registers for correction of curvature,
Enable Pin Allowing a A Shutdown Mode
tempco, and accuracy on a CMOS bandgap
20mA Output Current
architecture that allows package level programming
Voltage Options 1.8V, 2.048V, 2.5V, 3.0V, 3.3V,
to overcome assembly shift. The shifts in voltage
4.096V
accuracy and tempco during assembly of die into
plastic packages limit the accuracy of references
Custom Voltage Options Available (1.8V to
trimmed with laser techniques.
4.096V)
Unlike other LDO references, the LM4132 is capable
V
IN
Range of V
REF
+ 400mV to 5.5V @ 10mA
of delivering up to 20mA and does not require an
Stable with Low ESR Ceramic Capacitors
output capacitor or buffer amplifier. These
SOT23-5 Package
advantages and the SOT23 packaging are important
for space-critical applications.
APPLICATIONS
Series references provide lower power consumption
Instrumentation & Process Control
than shunt references, since they do not have to idle
the maximum possible load current under no load
Test Equipment
conditions. This advantage, the low quiescent current
Data Acquisition Systems
(60µA), and the low dropout voltage (400mV) make
Base Stations
the LM4132 ideal for battery-powered solutions.
Servo Systems
The LM4132 is available in five grades (A, B, C, D
Portable, Battery Powered Equipment
and E) for greater flexibility. The best grade devices
(A) have an initial accuracy of 0.05% with a specified
Automotive & Industrial
temperature coefficient of 10ppm/°C or less, while the
Precision Regulators
lowest grade parts (E) have an initial accuracy of
Battery Chargers
0.5% and a tempco of 30ppm/°C.
Communications
Medical Equipment
Typical Application Circuit
*Note: The capacitor C
IN
is required and the capacitor C
OUT
is optional.
1
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
2All trademarks are the property of their respective owners.
PRODUCTION DATA information is current as of publication date.
Copyright © 2005–2013, Texas Instruments Incorporated
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.