Datasheet
LM95221
www.ti.com
SNIS134B –MAY 2004–REVISED MARCH 2013
Figure 7. Conversion Rate Effect on Power Supply Current
POWER-ON-DEFAULT STATES
LM95221 always powers up to these known default states. The LM95221 remains in these states until after the
first conversion.
1. Command Register set to 00h
2. Local Temperature set to 0°C
3. Remote Diode Temperature set to 0°C until the end of the first conversion
4. Status Register depends on state of thermal diode inputs
5. Configuration register set to 00h; continuous conversion, time = 66ms
SMBus INTERFACE
The LM95221 operates as a slave on the SMBus, so the SMBCLK line is an input and the SMBDAT line is
bidirectional. The LM95221 never drives the SMBCLK line and it does not support clock stretching. According to
SMBus specifications, the LM95221 has a 7-bit slave address. All bits A6 through A0 are internally programmed
and can not be changed by software or hardware. The LM95221 has the following SMBus slave address:
Version A6 A5 A4 A3 A2 A1 A0
LM95221 0 1 0 1 0 1 1
TEMPERATURE DATA FORMAT
Temperature data can only be read from the Local and Remote Temperature registers .
Remote temperature data is represented by an 11-bit, two's complement word or unsigned binary word with an
LSb (Least Significant Bit) equal to 0.125°C. The data format is a left justified 16-bit word available in two 8-bit
registers. Unused bits will always report "0".
Copyright © 2004–2013, Texas Instruments Incorporated Submit Documentation Feedback 9
Product Folder Links: LM95221