User manual

Step 4: Verifying the Installation
11
Installing the Evaluation Module and the C Source Debugger
5. Step 4: Verifying the Installation
To ensure that you have correctly installed the EVM and debugger software,
enter this command at the system prompt:
evm30 c:\c3xhll\sample
You should see a display similar to this one:
DISASSEMBLY CPU
MEMORYCOMMAND
>>>
PC 00f00076
R0 00000003
R2 00000007
R4 00000000
R6 00000000
AR0 00001802
AR2 00000000
AR4 00000000
AR6 00000000
IR0 00000000
ST 00000000
RS 00000000
DP 00000000
IE 00000000
SP 00000755
R1 00000005
R3 00000000
R5 00000000
R7 00000000
AR1 00000000
AR3 00000000
AR5 00000000
AR7 00000000
IR1 00000000
RC 00000000
RE 00000000
BK 00000000
IF 00000000
f00075 00f000b2 ABSI 178,DP
f00076 087000f0 c_int00: LDI 240,DP
f00077 08340074 LDI @074H,SP
f00078 080b0014 LDI SP,AR3
f00079 087000f0 LDI 240,DP
f0007a 08280075 LDI @075H,AR0
f0007b 04e8ffff CMPI −1,AR0
f0007c 6a05000c BZ f00089
f0007d 08412001 LDI *AR0++(1),R1
f0007e 6a250008 BZD f00089
f0007f 08492001 LDI *AR0++(1),AR1
f00080 08402001 LDI *AR0++(1),R0
f00081 18610001 SUBI 1,R1
f00082 139b9991 RPTS R1
f00083 da002120 LDI *AR0++(1),R0 || STI
000000
000004
000008
00000c
000010
000014
0000004b
00000043
00000047
00000000
00000000
00000000
00000040
00000044
00000048
00000000
00000000
00000000
00000041
00000045
00000049
00000000
00000000
00000000
00000042
00000046
0000004a
00000000
00000000
00000000
TMS3203x Debugger
Copyright (c) 1989, 1993 Texas In
TMS320C3x
Loading sample.out
Done
Load Break Watch Memory MoDe Run=F5 Step=F8 Next=F10Color Pin
- If you see a display similar to this one, you have correctly installed your
EVM and debugger.
- If you see a display and the lines of code show ADD instructions or say
Invalid address, your EVM board may not be installed snugly. Check your
board to see if it is correctly installed, and re-enter the command above.
- If you don’t see a display, then your debugger or board may not be installed
properly. Go back through the installation instructions and be sure that you
have followed each step correctly; then re-enter the command above.