Incor User's Guide Converter SLVP089

Design Procedures
2-9
Design Procedure
Figure 23 shows the bode plot for the compensation network.
Figure 23. Bode Plot
25
20
10
0
Gain dB (Solid)
30
40
Frequency Hz
45
35
15
90
70
50
30
10
10
30
50
90
Phase Degrees (Dashed)
10 10
2
10
3
10
4
10
5
5
70
Note from the output response shown in Figure 24 that the minimum phase
margin is 40 degrees and the bandwidth is 18 kHz under nominal operating
conditions.
Figure 24. Output Response