Datasheet

SN65HVD233-HT
www.ti.com
SLLS933F NOVEMBER 2008REVISED AUGUST 2012
3.3-V CAN TRANSCEIVER
Check for Samples: SN65HVD233-HT
1
FEATURES
SUPPORTS EXTREME TEMPERATURE
APPLICATIONS
2
Bus-Pin Fault Protection Exceeds ±36 V
Controlled Baseline
Bus-Pin ESD Protection Exceeds 16-kV Human
Body Model (HBM) One Assembly/Test Site
Compatible With ISO 11898 One Fabrication Site
Signaling Rates
(1)
up to 1 Mbps Available in Extreme (–55°C/210°C)
Temperature Range
(1)
Extended –7-V to 12-V Common-Mode Range
Extended Product Life Cycle
High-Input Impedance Allows for 120 Nodes
Extended Product-Change Notification
LVTTL I/Os Are 5-V Tolerant
Product Traceability
Adjustable Driver Transition Times for
Improved Signal Quality Texas Instruments high temperature products
utilize highly optimized silicon (die) solutions
Unpowered Node Does Not Disturb the Bus
with design and process enhancements to
Low-Current Standby Mode . . . 200 μA Typical
maximize performance over extended
Power-Up/Down Glitch-Free Bus Inputs and
temperatures.
Outputs
High Input Impedance With Low V
CC
DESCRIPTION/ORDERING INFORMATION
Monolithic Output During Power Cycling
The SN65HVD233 is used in applications employing
the controller area network (CAN) serial
Loopback for Diagnostic Functions Available
communication physical layer in accordance with the
DeviceNet™ Vendor ID #806
ISO 11898 standard, with the exception that the
(1)
The signaling rate of a line is the number of voltage
thermal shutdown is removed. As a CAN transceiver,
transitions that are made per second expressed in the units
the device provides transmit and receive capability
bps (bits per second).
between the differential CAN bus and a CAN
controller, with signaling rates up to 1 Mbps.
APPLICATIONS
Designed for operation in especially harsh
Down-Hole Drilling
environments, the device features cross wire,
High Temperature Environments
overvoltage, and loss-of-ground protection to ±36 V,
with common-mode transient protection of ±100 V.
Industrial Automation
This device operates over a –7-V to 12-V common-
DeviceNet™ Data Buses
mode range with a maximum of 60 nodes on a bus.
Smart Distributed Systems (SDS™)
If the common-mode range is restricted to the ISO
SAE J1939 Data Bus Interface
11898 standard range of –2 V to 7 V, up to 120
NMEA 2000 Data Bus Interface
nodes may be connected on a bus. This transceiver
interfaces the single-ended CAN controller with the
ISO 11783 Data Bus Interface
differential CAN bus found in industrial, building
CAN Data Bus Interface
automation, and automotive applications.
XXX
(1) Custom temperature ranges available
1
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
2DeviceNet is a trademark of Open DeviceNet Vendor Association.
PRODUCTION DATA information is current as of publication date.
Copyright © 2008–2012, Texas Instruments Incorporated
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.