Datasheet

V
CC
CANH
7
6
CANL
RXD
1
TXD
S
8
DOMINANT
TIME OUT
OVER
TEMPERATURE
LOGIC
OUTPUT
MODE SELECT
4
NC / V
RXD
/ FAULT (See Note A) V
CC
5 3
GND
2
UNDER
VOLTAGE
DOMINANT
TIME OUT
(See Note B)
V
CC
V
CC
or V
RXD
(See Note B)
FAULT LOGIC
MUX (See Note A)
SN65HVD255
SN65HVD256, SN65HVD257
www.ti.com
SLLSEA2C DECEMBER 2011REVISED SEPTEMBER 2013
'Turbo' CAN Transceivers for Higher Data Rates and Large Networks Including Features
for Functional Safety
Check for Samples: SN65HVD255, SN65HVD256, SN65HVD257
1
FEATURES
DESCRIPTION
This CAN transceiver meets the ISO1189-2 High
Meets the Requirements of ISO11898-2
Speed CAN (Controller Area Network) Physical Layer
'Turbo' CAN:
standard. It is designed for data rates in excess of 1
Short and Symmetrical Propagation Delay
Mbps for CAN in short networks, and enhanced
Times and Fast Loop Times for Enhanced
timing margin and higher data rates in long and
highly-loaded networks. The device provides many
Timing Margin
protection features to enhance device and CAN-
Higher Data Rates in CAN Networks
network robustness. The SN65HVD257 adds
I/O Voltage Range Supports 3.3V and 5V MCUs
additional features, allowing easy design of redundant
Ideal Passive Behavior When Unpowered
and multi-topology networks with fault indication for
higher levels of functional safety in the CAN system.
Bus and Logic Pins are High Impedance
(no load)
Power Up/Down With Glitch Free Operation
On Bus
Protection Features
HBM ESD Protection Exceeds ±12kV
Bus Fault Protection –27V to 40V
Undervoltage Protection on Supply Pins
Driver Dominant Time Out (TXD DTO)
SN65HVD257: Receiver Dominant Time Out
(RXD DTO)
SN65HVD257: FAULT Output Pin
Thermal Shutdown Protection
Characterized for 40°C to 125°C Operation
APPLICATIONS
A. Pin 5 function is device dependent; NC on
1Mbps Operation in Highly Loaded CAN
SN65HVD255, V
RXD
for RXD output level-
Networks Down to 10kbps Networks Using
shifting device on SN65HVD256, and
FAULT Output on SN65HVD257
TXD DTO
B. RXD logic output is driven to 5V V
CC
on
Industrial Automation, Control, Sensors and
5V-only supply devices (SN65HVD255,
Drive Systems
SN65HVD257) and driven to V
RXD
on
Building, Security and Climate Control
output level-shifting device (SN65HVD256).
Automation
C. RXD (Receiver) Dominant State Time Out
is a device dependent option available only
Telecom Base Station Status and Control
on SN65HVD257.
SN65HVD257: Functional Safety With
Figure 1. Functional Block Diagram
Redundant and Multi-topology CAN networks
CAN Bus Standards Such as CANopen,
DeviceNet, NMEA2000, ARNIC825, ISO11783,
CANaerospace
1
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
PRODUCTION DATA information is current as of publication date.
Copyright © 2011–2013, Texas Instruments Incorporated
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.