Datasheet


   
SCLS317N − MARCH 1996 − REVISED JUNE 2005
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
V
CC
T
A
= 25°C
MIN
MAX
UNIT
PARAMETER
V
CC
MIN TYP MAX
MIN
MAX
UNIT
2 V 1.9 2 1.9
I
= −50 µA
3 V 2.9 3 2.9
V
OH
4.5 V 4.4 4.5 4.4
V
V
OH
I
OH
= −4 mA
3 V 2.58 2.48
V
I
OH
= −8 mA
4.5 V 3.94 3.8
2 V 0.1 0.1
I
= 50 µA
3 V 0.1 0.1
V
OL
4.5 V 0.1 0.1
V
V
OL
I
OL
= 4 mA
3 V 0.36 0.44
V
I
OL
= 8 mA
4.5 V 0.36 0.44
I
I
V
I
= 5.5 V or GND 0 V to 5.5 V ±0.1 ±1 µA
I
CC
V
I
= V
CC
or GND, I
O
= 0 5.5 V 1 10 µA
C
i
V
I
= V
CC
or GND 5 V 2 10 10 pF
switching characteristics over recommended operating free-air temperature range,
V
CC
= 3.3 V ± 0.3 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
TO
LOAD
T
A
= 25°C
MIN
MAX
UNIT
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
LOAD
CAPACITANCE
MIN TYP MAX
MIN
MAX
UNIT
t
PLH
A or B
Y
C
L
= 15 pF
5.5 7.9 1 9.5
ns
t
PHL
A or B Y C
L
= 15 pF
5.5 7.9 1 9.5
ns
t
PLH
A or B
Y
C
L
= 50 pF
8 11.4 1 13
ns
t
PHL
A or B Y C
L
= 50 pF
8 11.4 1 13
ns
switching characteristics over recommended operating free-air temperature range,
V
CC
= 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
TO
LOAD
T
A
= 25°C
MIN
MAX
UNIT
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
LOAD
CAPACITANCE
MIN TYP MAX
MIN
MAX
UNIT
t
PLH
A or B
Y
C
L
= 15 pF
3.8 5.5 1 6.5
ns
t
PHL
A or B Y C
L
= 15 pF
3.8 5.5 1 6.5
ns
t
PLH
A or B
Y
C
L
= 50 pF
5.3 7.5 1 8.5
ns
t
PHL
A or B Y C
L
= 50 pF
5.3 7.5 1 8.5
ns
operating characteristics, V
CC
= 5 V, T
A
= 25°C
PARAMETER TEST CONDITIONS TYP UNIT
C
pd
Power dissipation capacitance No load, f = 1 MHz 14 pF