VLYNQ Port User's Guide

www.ti.com
Peripheral Architecture
DM643x VLYNQ Module:
4C00 : 0054h Initial address at the slave configuration bus
0000 : 0054h Initial address [25:0] at the slave configuration bus interface
subtract 0000 : 0000h TX address map register (there is no need to change the reset value of the
DM643x device for this register)
0000 : 0054h
Remote VLYNQ Module:
0000 : 0054h Initial address from the RX serial interface
compare 0000 : 0100h RX address map size 1 register
0000 : 0054h
add 0800 : 0000h RX address map offset 1 register
0800 : 0054h Translated address to remote device
The local address 4C00:0054h (or 0000 0054h) was translated to 0800:0054h on the remote VLYNQ
device in Table 3 .
Table 3 shows the address map register configuration when the DM643x device is receiving data from the
remote device.
Table 3. Address Translation Example (Single Mapped Region)
Register DM643x VLYNQ Module Remote VLYNQ Module
TX Address Map Do not care 0400 : 0000h
RX Address Map Size 1 0000 : 0100h Do not care
RX Address Map Offset 1 0200 : 0000h Do not care
RX Address Map Size 2 0000 : 0100h Do not care
RX Address Map Offset 2 8200 : 0000h Do not care
Remote VLYNQ Module:
0400 : 0154h Initial address at the slave configuration bus for the remote device
subtract 0400 : 0000h TX address map register
0000 : 0154h Translated address to remote device via serial interface
DM643x VLYNQ Module:
0000 : 0154h Initial address from the RX serial interface
compare 0000 : 0100h RX address map size 1 register
0000 : 0154h The RX packet address is greater than the value in the RX address map size 1
register
compare 0000 : 0200h RX address map size 1 register + RX address map size 2
Since the RX packet address < the RX address map size 1 register +
RX address map size 2 register
add 8200 : 0000h RX address map offset 2 register
subtract 0000 : 0100h RX address map size 1 register
8200 : 0054h Translated address to DM643x device
VLYNQ Port18 SPRU938B September 2007
Submit Documentation Feedback