User Guide

Chapter 7: Tables 118
Displaying the Table
The Table
To display the table, press y 0.
Note: The table abbreviates the values, if necessary.
Current cell
Current cell’s full value
Dependent-variable
values in the second
and third columns
Independent-variable
values in the first
column
Note: When the table first displays, the message “Press + for @Tbl” is on the entry line. This
message reminds you that you can press à to change
@Tbl at any time. When you press any key,
the message disappears.
Independent and Dependent Variables
The current graphing mode determines which independent and dependent variables are displayed
in the table (Chapter 1). In the table above, for example, the independent variable X and the
dependent variables
Y1 and Y2 are displayed because Func graphing mode is set.
Clearing the Table from the Home Screen or a Program
From the home screen, select the
ClrTable instruction from the CATALOG. To clear the table,
press Í.
From a program, select
9:ClrTable from the PRGM I/O menu or from the CATALOG. The table is
cleared upon execution. If
IndpntAsk is selected, all independent and dependent variable values
on the table are cleared. If
DependAsk is selected, all dependent variable values on the table are
cleared.
Graphing Mode
Independent Variable
Dependent Variable
Func (function) X Y1 through Y9, and Y0
Par (parametric) T X1T/Y1T through X6T/Y6T
Pol (polar)
q
r1 through r6
Seq (sequence) n u(n), v(n), and w(n)