User Manual

TI-83 Plus Communication Link 653
You attempt a data transfer from a TI-83 Plus to a TI-73 with data
other than real numbers, pics, real lists
L1
through
L6
or named lists
with
q
as part of the name.
Although a transmission error does not occur, these two conditions may
prevent successful transmission.
You try to use
Get(
with a calculator instead of a CBL 2/CBL or CBR.
You try to use
GetCalc(
with a TI-83 instead of a
TI-83 Plus Silver Edition or TI-83 Plus.
Insufficient Memory in Receiving Unit
During transmission, if the receiving unit does not have sufficient
memory to receive an item, the
Memory Full
menu is displayed on the
receiving unit.
To skip this item for the current transmission, select
1:Omit
.
Transmission resumes with the next item.
To cancel the transmission and exit receive mode, select
2:Quit
.