Page 0/Register 34: Left-AGC Noise Gate Debounce Register
BIT READ/ RESET DESCRIPTION
WRITE VALUE
D7 D3 R/W 0000 0 Left-AGC Noise Detection Debounce Control
These times
(1)
are not accurate when double-rate audio mode is enabled.
0000 0: Debounce = 0 ms
0000 1: Debounce = 0.5 ms
0001 0: Debounce = 1 ms
0001 1: Debounce = 2 ms
0010 0: Debounce = 4 ms
0010 1: Debounce = 8 ms
0011 0: Debounce = 16 ms
0011 1: Debounce = 32 ms
0100 0: Debounce = 64 × 1 = 64 ms
0100 1: Debounce = 64 × 2 = 128 ms
0101 0: Debounce = 64 × 3 = 192 ms
1111 0: Debounce = 64 × 23 = 1472 ms
1111 1: Debounce = 64 × 24 = 1536 ms
D2 D0 R/W 000 Left-AGC Signal Detection Debounce Control
These times
(1)
are not accurate when double-rate audio mode is enabled.
000: Debounce = 0 ms
001: Debounce = 0.5 ms
010: Debounce = 1 ms
011: Debounce = 2 ms
100: Debounce = 4 ms
101: Debounce = 8 ms
110: Debounce = 16 ms
111: Debounce = 32 ms
(1) Time constants are valid when DRA is not enabled. The values would change when DRA is enabled
Page 0/Register 35: Right AGC Noise Gate Debounce Register
BIT READ/ RESET DESCRIPTION
WRITE VALUE
D7 D3 R/W 0000 0 Right AGC Noise Detection Debounce Control
These times
(1)
are not accurate when double-rate audio mode is enabled.
0000 0: Debounce = 0 ms
0000 1: Debounce = 0.5 ms
0001 0: Debounce = 1 ms
0001 1: Debounce = 2 ms
0010 0: Debounce = 4 ms
0010 1: Debounce = 8 ms
0011 0: Debounce = 16 ms
0011 1: Debounce = 32 ms
0100 0: Debounce = 64 × 1 = 64 ms
0100 1: Debounce = 64 × 2 = 128 ms
0101 0: Debounce = 64 × 3 = 192 ms
1111 0: Debounce = 64 × 23 = 1472 ms
1111 1: Debounce = 64 × 24 = 1536 ms
D2 D0 R/W 000 Right AGC Signal Detection Debounce Control
These times
(1)
are not accurate when double-rate audio mode is enabled.
000: Debounce = 0 ms
001: Debounce = 0.5 ms
010: Debounce = 1 ms
011: Debounce = 2 ms
100: Debounce = 4 ms
101: Debounce = 8 ms
110: Debounce = 16 ms
111: Debounce = 32 ms
(1) Time constants are valid when DRA is not enabled. The values would change when DRA is enabled.
Copyright © 2007 2008, Texas Instruments Incorporated Submit Documentation Feedback 61