Datasheet

TLV320AIC3105
www.ti.com
......................................................................................................................................... SLAS513B FEBRUARY 2007 REVISED DECEMBER 2008
Page 0/Register 94: Module Power Status Register
BIT READ/ RESET DESCRIPTION
WRITE VALUE
D7 R 0 Left-DAC Power Status
0: Left DAC is not fully powered up.
1: Left DAC is fully powered up.
D6 R 0 Right DAC Power Status
0: Right DAC is not fully powered up.
1: Right DAC is fully powered up.
D5 R 0 Reserved. Write only 0 to this bit.
D4 R 0 LEFT_LOP/M Power Status
0: LEFT_LOP/M output driver is powered down.
1: LEFT_LOP/M output driver is powered up.
D3 R 0 RIGHT_LOP/M Power Status
0: RIGHT_LOP/M is not fully powered up.
1: RIGHT_LOP/M is fully powered up.
D2 R 0 HPLOUT Driver Power Status
0: HPLOUT Driver is not fully powered up.
1: HPLOUT Driver is fully powered up.
D1 R 0 HPROUT Driver Power Status
0: HPROUT Driver is not fully powered up.
1: HPROUT Driver is fully powered up.
D0 R 0 Reserved. Do not write to this register bit.
Page 0/Register 95: Output Driver Short-Circuit Detection Status Register
BIT READ/ RESET DESCRIPTION
WRITE VALUE
D7 R 0 HPLOUT Short-Circuit Detection Status
0: No short circuit detected at HPLOUT
1: Short circuit detected at HPLOUT
D6 R 0 HPROUT Short-Circuit Detection Status
0: No short circuit detected at HPROUT
1: Short circuit detected at HPROUT
D5 R 0 HPLCOM Short-Circuit Detection Status
0: No short circuit detected at HPLCOM
1: Short circuit detected at HPLCOM
D4 R 0 HPRCOM Short-Circuit Detection Status
0: No short circuit detected at HPRCOM
1: Short circuit detected at HPRCOM
D3 R 0 HPLCOM Power Status
0: HPLCOM is not fully powered up.
1: HPLCOM is fully powered up.
D2 R 0 HPRCOM Power Status
0: HPRCOM is not fully powered up.
1: HPRCOM is fully powered up.
D1 D0 R 00 Reserved. Do not write to these register bits.
Copyright © 2007 2008, Texas Instruments Incorporated Submit Documentation Feedback 75
Product Folder Link(s): TLV320AIC3105