Datasheet

TMP512
TMP513
SBOS491A JUNE 2010 REVISED MAY 2011
www.ti.com
Bus Voltage Negative Limit Register 0Fh (Read/Write)
At full-scale range = 32V (decimal = 8000, hex = 1F40), and LSB = 4mV.
BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
BIT
BUO12 BUO11 BUO10 BUO9 BUO8 BUO7 BUO6 BUO5 BUO4 BUO3 BUO2 BUO1 BUO0
NAME
POR
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
VALUE
Power Limit Register 10h (Read/Write)
At full-scale range, same as the Power Register (06h).
BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
BIT
PW15 PW14 PW13 PW12 PW11 PW10 PW9 PW8 PW7 PW6 PW5 PW4 PW3 PW2 PW1 PW0
NAME
POR
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
VALUE
Local Temperature Limit Register 11h, Remote Temperature Limit 1 Register 12h, Remote Temperature
Limit 2 Register 13h, Remote Temperature Limit 3 Register 14h (TMP513 Only) (Read/Write)
BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
BIT
TH12 TH11 TH10 TH9 TH8 TH7 TH6 TH5 TH4 TH3 TH2 TH1 TH0
NAME
POR
0 0 1 0 1 0 1 0 1 0 0 0 0 0 0 0
VALUE
The data format is 13 bits.
TH12TH0: Temperature Limit
Bits 15-3 Shows the temperature limit.
Shunt Calibration Register 15h (Read/Write)
Current and power calibration are set in the Calibration Register. Note that bit D0 is not used in the calculation.
This register sets the current that corresponds to a full-scale drop across the shunt. Full-scale range and the LSB
of the current and power measurement depend on the value entered in this register. See the Programming the
TMP512/13 Power Measurement Engine section. This register is suitable for use in overall system calibration.
Note that the '0' POR values are all default.
BIT # D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
(1)
BIT
FS15 FS14 FS13 FS12 FS11 FS10 FS9 FS8 FS7 FS6 FS5 FS4 FS3 FS2 FS1 FS0
NAME
POR
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
VALUE
(1) D0 is a void bit and is always '0'. It is not possible to write a '1' to D0.
46 Copyright © 20102011, Texas Instruments Incorporated