4.13 MDIO User PHY Select Register 0 (USERPHYSEL0)
MDIO Registers
The MDIO user PHY select register 0 (USERPHYSEL0) is shown in Figure 27 and described in Table 26 .
Figure 27. MDIO User PHY Select Register 0 (USERPHYSEL0)
31 16
Reserved
R-0
15 8 7 6 5 4 0
Reserved LINKSEL LINKINTENB Reserved PHYADRMON
R-0 R/W-0 R/W-0 R-0 R/W-0
LEGEND: R = Read only; R/W = Read/Write; - n = value after reset
Table 26. MDIO User PHY Select Register 0 (USERPHYSEL0) Field Descriptions
Bit Field Value Description
31-8 Reserved 0 Reserved
7 LINKSEL Link status determination select bit. Default value is 0 which implies that the link status is
determined by the MDIO state machine. This is the only option supported on this device.
6 LINKINTENB Link change interrupt enable. Set to 1 to enable link change status interrupts for PHY address
specified in PHYADRMON. Link change interrupts are disabled if this bit is set to 0.
0 Link change interrupts are disabled
1 Link change status interrupts for PHY address specified in PHYADDRMON bits are enabled
5 Reserved 0 Reserved
4-0 PHYADRMON PHY address whose link status is to be monitored