Load Switch EVM User's Guide

4.1 Recommended Test Equipment
4.2 Calculating Voltage Drop and Load Current
Oscilloscope
Voltage
probe
3.6 V, 2 A Max
7” twisted pair, #20 AWG
+
IN
+
OUT
EVM
Voltage
probe
Chapter 4
SLVU286 January 2009
EVM Setup
The following test equipment is recommended:
Two-channel storage oscilloscope
Current probe
Voltage probe
3.6 V at 2-A power supply
Volt-ohm meter
The user should read the applicable data sheet before using the EVM.
Figure 4-1 shows the EVM test setup for measuring input and output voltage. The load switch is enabled
into a passive on-board load for this measurement. After measuring the voltages at both V
IN
and V
OUT
, the
voltage drop across the switch as well as the load current can be calculated from the following equations:
V
DROP
= V
IN
V
OUT
I
LOAD
= V
OUT
/ R
LOAD
Figure 4-1. EVM Setup For Calculating Voltage Drop and Load Current
SLVU286 January 2009 EVM Setup 13
Submit Documentation Feedback