Datasheet

2 Electrical Specifications
2.1 Electrostatic Discharge
3 Schematic
3.1 EVM Options
Electrical Specifications
www.ti.com
The EVM meets the electrical specifications in Table 1 over the recommended operating
junction-temperature range of -40 ° C T
J
105 ° C for the DRV (SON) package and -40 ° C T
J
125 ° C for
the DBV (SOT23-6) package.
Table 1. EVM Electrical Specifications
MA
PARAMETER CONDITION MIN TYP UNIT
X
Input voltage, V
IN
J1 2.5 6.5 V
Short-circuit output J2 shorting-jumper is absent, J3 is short 0.28 0.47 0.61 A
current-limit, I
LIMIT
circuited, TPS2552/3 is enabled
J2 shorting-jumper is present, J3 is short 0.70 1.02 1.24
circuited, TPS2552/3 is enabled
The EVM has been tested to IEC 61000-4-2. The level used was 8-kV contact discharge and 15-kV air
discharge. Surges were applied to the EVM input and output. No damage to the TPS2552/3 was
observed.
Table 2. EVM Options
HPA364 DEVICE DEVICE PACKAGE ENABLE
-1 TPS2552DBV SOT-23-6 Active Low
-2 TPS2553DBV SOT-23-6 Active High
-3 TPS2552DBV-1 SOT-23-6 Active Low
-4 TPS2553DBV-1 SOT-23-6 Active High
-5 TPS2552DRV SON Active Low
-6 TPS2553DRV SON Active High
-7 TPS2552DRV-1 SON Active Low
-8 TPS2553DRV-1 SON Active High
TPS2552/3, Power-Distribution Switch2 SLUU339 December 2008
With Adjustable Current-Limit EVM
Submit Documentation Feedback