Datasheet

www.ti.com
Configurations
Table 2. Switching Frequency Selection
Jumper set to Resistor (RF) Connections(Ω) Switching Frequency(kHz)
Top(1-2 pin shorted) 0 250
2
nd
(3-4 pin shorted) 187k 300
3
rd
(5-6 pin shorted) 619k 400
4
th
(7-8 pin shorted) Open 500
5
th
(9-10 pin shorted) 866k 600
6
th
(11-12 pin shorted) 309k 750
7
th
(13-14 pin shorted) 124k 850
Bottom(15-16 pin shorted) 0 970
5.2 Soft Start Selection
The soft start time can be set by J4.
Default setting: 1.4ms
Table 3. Soft Start Time Selection
Jumper set to R
MODE
Connections(Ω) Soft Start Time(ms)
Top(1-2 pin shorted) 39.2k 0.7
2
nd
(3-4 pin shorted) 100k 1.4
3
rd
(5-6 pin shorted) 200k 2.8
Bottom(7-8 pin shorted) 475k 5.6
5.3 Mode Selection
The MODE can be set by J5.
Default setting: Auto Skip
Table 4. MODE Selection
Jumper set to MODE Selection
Top(1-2 pin shorted) Auto Skip
Bottom(3-4 pin shorted) Forced CCM
5.4 Enable Selection
The controller can be enabled and disabled by J6.
Default setting: Jumper shorts on J6 to disable the controller
Table 5. Enable Selection
Jumper set to Enable Selection
Jumper shorts on J6 Disable the controller
No Jumper shorts on J6 Enable the controller
7
SLVU728May 2012 High Efficiency 14A Synchronous Buck Converter with Eco-Mode™
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated