Datasheet
TPS59124
SLUSA58 –JULY 2010
www.ti.com
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
ORDERING INFORMATION
(1)
ORDERING MINIMUM
OUTPUT
T
A
PACKAGE PART PINS ORDER ECO PLAN
SUPPLY
NUMBER QUANTITY
Plastic Quad TPS59124RGET 250
Green (RoHS and
–40°C to 85°C 24 Tape-and-Reel
Flat Pack (QFN)
no Sb/Br)
TPS59124RGER 3000
(1) All packaging options have Cu NIPDAU lead/ball finish.
ABSOLUTE MAXIMUM RATINGS
(1)
over operating free-air temperature range (unless otherwise noted)
VALUE UNIT
VBST1, VBST2 –0.3 to 36
Input voltage
VBST1, VBST2 (wrt LLx) –0.3 to 6 V
range
V5IN, V5FILT, EN1, EN2, VFB1, VFB2, TRIP1, TRIP2, VO1, VO2, TONSEL –0.3 to 6
DRVH1, DRVH2 –1 to 36
DRVH1, DRVH2 (wrt LLx) –0.3 to 6
Output voltage
LL1, LL2 –2 to 30 V
range
PGOOD1, PGOOD2, DRVL1, DRVL2 –0.3 to 6
PGND1, PGND2 –0.3 to 0.3
T
A
Operating ambient temperature range –40 to 85 °C
T
stg
Storage temperature range –55 to 150 °C
T
J
Junction temperature range –40 to 125 °C
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. All voltage
values are with respect to the network ground terminal unless otherwise noted
DISSIPATION RATINGS
T
A
<25°C DERATING FACTOR T
A
= 85°C
PACKAGE
POWER RATING ABOVE T
A
= 25°C POWER RATING
24-pin QFN
(1)
2.33 W 23.3 mW/°C 0.93 W
(1) Enhanced thermal conductance by 2 × 2 thermal vias beneath thermal pad.
RECOMMENDED OPERATING CONDITIONS
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
Supply input voltage range V5IN, V5FILT 4.5 5.5 V
VBST1, VBST2 –0.1 34
Input voltage range VBST1, VBST2 (wrt LLx) –0.1 5.5 V
EN1, EN2, VFB1, VFB2, TRIP1, TRIP2, VO1, VO2, TONSEL –0.1 5.5
DRVH1, DRVH2 –0.8 34
DRVH1, DRVH2 (wrt LLx) –0.1 5.5
Output voltage range LL1, LL2 –1.8 28 V
PGOOD1, PGOOD2, DRVL1, DRVL2 –0.1 5.5
PGND1, PGND2 –0.1 0.1
T
A
Operating ambient temperature range –40 85 °C
2 Submit Documentation Feedback Copyright © 2010, Texas Instruments Incorporated