Datasheet

ELECTRICAL CHARACTERISTICS
TPS62000, TPS62001, TPS62003
TPS62004, TPS62005, TPS62006
TPS62007, TPS62008
SLVS294E SEPTEMBER 2000 REVISED AUGUST 2008 ...........................................................................................................................................
www.ti.com
over recommended operating free-air temperature range, V
I
= 3.6 V, V
O
= 2.5 V, I
O
= 300 mA, EN = V
IN
, ILIM = V
IN
, T
A
=
40 ° C to 85 ° C (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
V
O
Adjustable output voltage range TPS62000 0.8 5.5 V
V
ref
Reference voltage TPS6200x 0.45 V
V
I
= 2.5 V to 5.5 V; 0 mA I
O
600 mA 3% 4%
TPS62000
adjustable
10 mA < I
O
600 mA 3% 3%
V
I
= 2.5 V to 5.5 V; 0 mA I
O
600 mA 3% 4%
TPS62001
0.9 V
10 mA < I
O
600 mA 3% 3%
V
I
= 2.5 V to 5.5 V; 0 mA I
O
600 mA 3% 4%
TPS62002
1 V
10 mA < I
O
600 mA 3% 3%
V
I
= 2.5 V to 5.5 V; 0 mA I
O
600 mA 3% 4%
TPS62003
1.2 V
10 mA < I
O
600 mA 3% 3%
V
I
= 2.5 V to 5.5 V; 0 mA I
O
600 mA 3% 4%
TPS62004
V
O
Fixed output voltage
(1)
V
1.5 V
10 mA < I
O
600 mA 3% 3%
V
I
= 2.5 V to 5.5 V; 0 mA I
O
600 mA 3% 4%
TPS62005
1.8 V
10 mA < I
O
600 mA 3% 3%
V
I
= 2.5 V to 5.5 V; 0 mA I
O
600 mA 3% 4%
TPS62008
1.9 V
10 mA < I
O
600 mA 3% 3%
V
I
= 2.7 V to 5.5 V; 0 mA I
O
600 mA 3% 4%
TPS62006
2.5 V
10 mA < I
O
600 mA 3% 3%
V
I
= 3.6 V to 5.5 V; 0 mA I
O
600 mA 3% 4%
TPS62007
3.3 V
10 mA < I
O
600 mA 3% 3%
Line regulation V
I
= V
O
+ 0.5 V (min. 2 V) to 5.5 V, I
O
= 10 mA 0.05 %/V
Load regulation V
I
= 5.5 V; I
O
= 10 mA to 600 mA 0.6%
V
I
= 5 V; V
O
= 3.3 V; I
O
= 300 mA
η Efficiency 95%
VI = 3.6 V; V
O
= 2.5 V; I
O
= 200 mA
Start-up time I
O
= 0 mA, time from active EN to V
O
0.4 2 ms
(1) The output voltage accuracy includes line and load regulation over the full temperature range, T
A
= 40 ° C to 85 ° C.
8 Submit Documentation Feedback Copyright © 2000 2008, Texas Instruments Incorporated
Product Folder Link(s): TPS62000, TPS62001, TPS62003 TPS62004, TPS62005, TPS62006 TPS62007, TPS62008