Datasheet

Setup and Results
www.ti.com
Figure 2 shows typical start from Vin = 4.2-V into a load of 12-.
Figure 2. Turn ON into Load, Vin = 4.2 V
2.4 Output Ripple
Output ripple occurs at the switching frequency of 2.25 -MHz, and with the recommended L and output C,
is low. Amplitude of the ripple varies, depending on load current and input voltage. Ensure that the
oscilloscope probe is connected as close as possible to the output capacitor, with a short ground lead, for
accurate measurements. Resistance in trace and leads adds to output ripple, and ground lead length
increases the amplitude of switching spikes.
Figure 3. Output Ripple Vin 2.2 V
4
TPS63036EVM-163 SLVU752August 2012
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated