Datasheet
        
          
SCDS172A - JULY 2004 − REVISED DECEMBER 2004
6
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range,
V
CC
 = 3.3 V   0.3 V (unless otherwise noted)
†
PARAMETER TEST CONDITIONS MIN TYP
‡
MAX UNIT
V
IK
EN, IN V
CC
 = 3 V, I
IN
 = −18 mA −1.8 V
I
IH
EN, IN V
CC
 = 3.6 V, V
IN
 and V
EN
 = 5.5 V ±1 µA
I
IL
EN, IN V
CC
 = 3.6 V, V
IN
 and V
EN
 = GND ±1 µA
I
OZ
§
V
CC
 = 3.6 V, V
O
 = 0 to 5.5 V, V
I
 = 0, Switch OFF ±1 µA
I
OS
¶
V
CC
 = 3.6 V, V
O
 = 0.5 V
CC
, V
I
 = 0, Switch ON 50 mA
I
off
V
CC
 = 0, V
O
 = 0 to 5.5 V, V
I
 = 0 1 µA
I
CC
V
CC
 = 3.6 V, I
I/O
 = 0, Switch ON or OFF 0.7 1.5 mA
∆I
CC
EN, IN V
CC
 = 3.6 V, One input at 3 V, Other inputs at V
CC
 or GND 30 µA
I
CCD
V
CC
 = 3.6 V,
D and S ports open,
V
EN
 = GND,
V
IN
 input switching 50% duty cycle
0.35
mA/
MHz
C
IN
EN, IN V
IN
 or V
EN
 = 5.5 V, 3.3 V or 0, f = 1 MHz 2.5 3.5 pF
C
OFF
D port
V
I
 = 5.5 V, 3.3 V, or 0,
f = 1 MHz,
Outputs open,
Switch OFF
5.5 7
pF
C
OFF
S port
V
I
 = 5.5 V, 3.3 V, or 0,
f = 1 MHz,
Outputs open,
Switch OFF
3.5 5
pF
C
ON
V
I
 = 5.5 V, 3.3 V, or 0, f = 1 MHz, Outputs open, Switch ON 10.5 14 pF
r
on
#
V
CC
 = 3 V
V
I
 = 1 V, I
O
 = 13 mA 3 6
Ω
r
on
#
V
CC
 = 3 V
V
I
 = 2 V, I
O
 = 26 mA 3 6
Ω
r
on(flat)
||
V
CC
 = 3.3 V, V
I
 = 0 to V
CC
, I
O
 = 26 mA 1 Ω
†
V
I
, V
O
, I
I
, and I
O
 refer to I/O pins.
‡
All typical values are at V
CC
 = 3.3 V (unless otherwise noted), T
A
 = 25°C.
§
For I/O ports, the parameter I
OZ
 includes the input leakage current.
¶
The I
OS
 test is applicable to only one ON channel at a time. The duration of this test is less than 1 s.
#
Measured by the voltage drop between the D and S terminals at the indicated current through the switch. ON-state resistance is determined by
the lower of the voltages of the two (D or S) terminals.
||
r
on(flat)
 is the difference of r
on
 in a given channel at specified voltages.
switching characteristics over recommended operating free-air temperature range,
V
CC
 = 3.3 V   0.3 V, R
L
 = 75 Ω, C
L
 = 20 pF (unless otherwise noted) (see Figures 6 and 7)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
MIN TYP MAX UNIT
t
pd(s)
IN
D 2 5 ns
t
ON
IN or EN
S 4 7 ns
t
OFF
IN or EN
S 2 7 ns
dynamic characteristics over recommended operating free-air temperature range,
V
CC
 = 3.3 V   0.3 V (unless otherwise noted)
PARAMETER TEST CONDITIONS TYP
‡
UNIT
D
G
k
R
L
 = 150 Ω, f = 3.58 MHz, See Figure 7 0.2 %
D
P
k
R
L
 = 150 Ω, f = 3.58 MHz, See Figure 7 0.1 °
B
W
R
L
 = 150 Ω, See Figure 8 500 MHz
X
TALK
R
L
 = 150 Ω, f = 10 MHz, R
IN
 = 10 Ω, See Figure 9 −80 dB
O
IRR
R
L
 = 150 Ω, f = 10 MHz, See Figure 10 −60 dB
‡
All typical values are at V
CC
 = 3.3 V (unless otherwise noted), T
A
 = 25°C.
k
D
G
 and D
P
 are expressed in absolute magnitude.