Datasheet
TVP7002
SLES206C –MAY 2007–REVISED APRIL 2013
www.ti.com
Input Mux Select 1
Subaddress 19h Default (00h)
7 6 5 4 3 2 1 0
SOG Select [1:0] Red Select [1:0] Green Select [1:0] Blue Select [1:0]
SOG Select [1:0]: Selects one of three SOG inputs.
00 = SOGIN_1 input selected (default)
01 = SOGIN_2 input selected
10 = SOGIN_3 input selected
11 = Reserved
Red Select [1:0]: Selects one of three R/Pr inputs.
00 = RIN_1 input selected (default)
01 = RIN_2 input selected
10 = RIN_3 input selected
11 = Reserved
Green Select [1:0]: Selects one of four G/Y inputs.
00 = GIN_1 input selected (default)
01 = GIN_2 input selected
10 = GIN_3 input selected
11 = GIN_4 input selected
Blue Select [1:0]: Selects one of three B/Pb inputs.
00 = BIN_1 input selected (default)
01 = BIN_2 input selected
10 = BIN_3 input selected
11 = Reserved
36 Submit Documentation Feedback Copyright © 2007–2013, Texas Instruments Incorporated
Product Folder Links: TVP7002