Datasheet

UAF42
UAF42
High-Pass
Out
R
R
R
1000pF
(1)
In
2
In
3
In
1
R
1000pF
(1)
Band-Pass
Out
Low-Pass
Out
GND
V+
V-
R=50kW 0.5%±
UAF42
www.ti.com
SBFS002B JULY 1992REVISED OCTOBER 2010
UNIVERSAL ACTIVE FILTER
Check for Samples: UAF42
1
FEATURES
DESCRIPTION
2
VERSATILE:
The UAF42 is a universal active filter that can be
configured for a wide range of low-pass, high-pass,
Low-Pass, High-Pass
and band-pass filters. It uses a classic state-variable
Band-Pass, Band-Reject
analog architecture with an inverting amplifier and two
SIMPLE DESIGN PROCEDURE
integrators. The integrators include on-chip 1000pF
ACCURATE FREQUENCY AND Q: capacitors trimmed to 0.5%. This architecture solves
one of the most difficult problems of active filter
Includes On-Chip 1000pF ±0.5% Capacitors
design—obtaining tight tolerance, low-loss capacitors.
APPLICATIONS
A DOS-compatible filter design program allows easy
implementation of many filter types, such as
TEST EQUIPMENT
Butterworth, Bessel, and Chebyshev. A fourth,
COMMUNICATIONS EQUIPMENT
uncommitted FET-input op amp (identical to the other
MEDICAL INSTRUMENTATION
three) can be used to form additional stages, or for
DATA ACQUISITION SYSTEMS
special filters such as band-reject and Inverse
Chebyshev.
MONOLITHIC REPLACEMENT FOR UAF41
The classical topology of the UAF42 forms a
time-continuous filter, free from the anomalies and
switching noise associated with switched-capacitor
filter types.
The UAF42 is available in 14-pin plastic DIP and
SOIC-16 surface-mount packages, specified for the
–25°C to +85°C temperature range.
blank
blank
blank
blank
NOTE: (1) ±0.5%.
1
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas
Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
2All trademarks are the property of their respective owners.
PRODUCTION DATA information is current as of publication date.
Copyright © 1992–2010, Texas Instruments Incorporated
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.