Datasheet

1
FEATURES APPLICATIONS
DESCRIPTION
UCD 9080
EN[1:7]
SDA
SCL
VCC
VSS
MON [1:8]
A1
ROSC
RST
XIN
TEST
10kW
100kW
10kW
10kW
3.3 V
3.3 V 3.3 V
3.3 V
3.3 V
3.3 V
3.3 V
0.01 Fm
1 Fm
A2
A3
A4
EN
EN
EN
V
OUT1
V
OUTX
V
OUT2
SlaveI C
Address
2
ToI C
2
MasterDevice
Digital
Outputs
EN8/
ADDR1/
GPO1
ADDR2/
GPO2
ADDR3/
GPO3
ADDR4/
GPO4
Power
Supply
1
Power
Supply
2
Power
Supply
X
UCD9080
www.ti.com
................................................................................................................................................... SLVS692E SEPTEMBER 2006 REVISED MAY 2008
8-CHANNEL POWER-SUPPLY SEQUENCER AND MONITOR
Telecommunications Switches
234
Single Supply Voltage: 3.3 V
Servers
Low Power Consumption
Networking Equipment
Sequences and Monitors up to Eight Voltage
Test Equipment
Rails
Any System Requiring Sequencing of Multiple
Rail Voltages Sampled Every 50 µ s With
Voltage Rails
3.2-mV Resolution
Four Configurable Digital Outputs for
Power-On Reset and Other Functions
The UCD9080 power-supply sequencer controls the
Configurable Rail-Enable Output Polarity
enable sequence of up to eight independent voltage
Flexible Rail Sequencing: Timeline (ms),
rails and provides four general-purpose digital
Parent Rail Regulation Window, Parent Rail
outputs. The device operates from a 3.3-V supply,
Achieving Defined Threshold
provides 3.2-mV resolution of voltage rails, and
requires no external memory or clock. The UCD9080
Under- and Overvoltage Thresholds: Settable
monitors the voltage rails independently at more than
Per-Rail
a 20-kHz rate and has a high degree of rail sequence
Regulation Expiration Time: Settable Per-Rail
and rail error-response configurability. The
Flexible Rail Shutdown: Parent Rail Shutdown
sequencing of rails can be based on time or on time
Can Shut Down Child Rails, Independent Rail
in conjunction with other rails achieving regulation or
Configuration a voltage threshold. In addition, each rail is monitored
for undervoltage and overvoltage glitches and
Per-Rail Alarm Conditions, With Timestamp:
thresholds. Each rail the UCD9080 monitors can be
Under- and Overvoltage Glitch, Sustained
configured to shut down a user-defined set of other
Under- and/or Overvoltage, Rail Did Not Start
rails, and alarm conditions are monitored on a per-rail
I
2
C Interface for Configuration and Monitoring
basis.
Microsoft
®
Windows
®
GUI for Configuration
Figure 1 shows the UCD9080 power-supply
and Monitoring
sequencer in a typical application.
Figure 1. Typical Application Diagram
1
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
2 TMS320 is a trademark of Texas Instruments.
3 Microsoft, Windows are registered trademarks of Microsoft Corporation.
4 All other trademarks are the property of their respective owners.
PRODUCTION DATA information is current as of publication date.
Copyright © 2006 2008, Texas Instruments Incorporated
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.

Summary of content (38 pages)