UCD9081
www.ti.com
SLVS813B –JUNE 2008–REVISED DECEMBER 2010
8-CHANNEL POWER SUPPLY SEQUENCER AND MONITOR WITH ERROR LOGGING
Check for Samples: UCD9081
1
FEATURES
• Microsoft™ Windows™ GUI for Configuration
and Monitoring
234
• Single Supply Voltage: 3.3V
• Low Power Consumption: 3mA Nominal
APPLICATIONS
Supply Current
• Telecommunications Switches
• Sequences and Monitors Eight Voltage Rails
• Servers
• Rail Voltages Sampled With 3.2-mV Resolution
• Networking Equipment
• Internal or External Voltage Reference
• Test Equipment
• Four Configurable Digital Outputs for
• Industrial
Power-On Reset and Other Functions
• Any System Requiring Sequencing of Multiple
• Configurable Digital Output Polarity
Voltage Rails
• Flexible Rail Sequencing Based On Timeline
(ms), Parent Rail Regulation Window, Or
DESCRIPTION
Parent Rail Achieving Defined Threshold
The UCD9081 power-supply sequencer controls the
• Independent Under- and Overvoltage
enable sequence of up to eight independent voltage
Thresholds Per Rail
rails and provides four general-purpose digital outputs
(GPO). The device operates from a 3.3-V supply,
• Configurable Regulation Expiration Times Per
provides 3.2-mV resolution of voltage rails, and
Rail
requires no external memory or clock. The UCD9081
• Flexible Alarm Processing: Ignore, Log Only,
monitors the voltage rails independently and has a
Retry n Times, Retry Continuously, Sequence,
high degree of rail sequence and alarm response
Parent Rail Can Shutdown Child Rails
options. The sequencing of rails can be based on
timed events or on timed events in conjunction with
• Alarm Conditions Logged With Timestamp:
other rails achieving regulation or a voltage threshold.
Under- and Overvoltage Glitch, Sustained
In addition, each rail is monitored for undervoltage
Under- and Overvoltage, Rail Did Not Start
and overvoltage glitches and thresholds. Each rail the
• On-chip Flash for Storing User Data
UCD9081 monitors can be configured to shut down a
• Error Logging to Flash for System Failure
user-defined set of other rails and GPOs, and alarm
conditions are monitored on a per-rail basis.
Analysis
• I
2
C™ Interface for Configuration and
Figure 1 shows the UCD9081 power-supply
Monitoring
sequencer in a typical application.
1
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas
Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
2PowerPAD, TMS320 are trademarks of Texas Instruments.
3Microsoft, Windows are trademarks of Microsoft Corporation.
4I
2
C is a trademark of Phillips Electronics.
PRODUCTION DATA information is current as of publication date.
Copyright © 2008–2010, Texas Instruments Incorporated
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.