T1 Remote Module Installation Link Wireless Telephone System Link 3000 MCU Part Number: 72-0059-06 Issue E
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU NOTICE SpectraLink Corporation has prepared this document for use by SpectraLink personnel and clients. The drawings and specifications contained herein are the property of SpectraLink and shall be neither reproduced in whole or in part without the prior written approval of SpectraLink, nor be implied to grant any license to make, use, or sell equipment manufactured in accordance herewith.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Note concerning the Master Control Unit: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU UL Information This symbol on the nameplate means the product is listed by Underwriter’s Laboratories, Inc. It is designed and manufactured to meet rigid U.L. safety standards against X-radiation, fire, casualty, and electrical hazards. The following are statements required for UL certification, related to safety procedures that must be adhered to during installation.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU FCC Information The Master Control Unit Complies with Part 68, FCC Rules FCC Registration Numbers: Link 3000: IYGUSA-7385Q-PX-T Ringer Equivalence: Link 3000: 0.3B SpectraLink Corporation Link 3000 Made in the USA This equipment complies with Part 68 of the FCC Rules.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Industry Canada (IC) Notice Notice: The Industry Canada (IC) label identifies certified equipment. This certification means that the equipment meets telecommunications network protective, operational, and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document(s). The department does not guarantee the equipment will operate to the user’s satisfaction.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Table of Contents 1. ABOUT THIS DOCUMENT 8 1.1 Contacting SpectraLink 8 1.2 Icons Used in this Document 8 1.3 Remote Installation Overview 9 1.4 Remote Installation Steps (Overview) 2. SITE PREPARATION 10 11 2.1 Required Materials Provided by Customer 11 2.2 T1 Configuration Requirements 12 2.3 Check Components 13 3. INSTALL T1 REMOTE MODULE AT LOCAL SITE 14 4. INSTALL SYSTEM AT REMOTE SITE 17 4.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 1. About This Document This document explains installation of the SpectraLink Link Wireless Telephone System (Link WTS, MCS300) Remote T1 Module. The installation process connects the Link 3000 MCU Primary Shelf in one location with an Expansion Shelf in a remote location, via T1 facilities. 1.1 Contacting SpectraLink SpectraLink wants every customer to have a successful installation.
SpectraLink Corporation 1.3 T1 Remote Module Installation Link WTS – Link 3000 MCU Remote Installation Overview Networking the Link WTS allows installation of expansion shelves at remote locations. T1 circuits are used to provide the connection from the System Controller shelf to each Remote Expansion shelf. As many as 19 expansion shelves may be supported by the system, and up to 18 of these shelves may be installed in remote locations from the System Controller shelf.
SpectraLink Corporation 1.4 T1 Remote Module Installation Link WTS – Link 3000 MCU Remote Installation Steps (Overview) Follow these steps to install the T1 Remote Module. Detailed instructions for each of these steps are contained in this document and other relevant documents in the Link 3000 MCU System Documentation. 1. Prepare site and check components. 2. Install T1 Remote Module at the local site (location where the Primary Shelf is located.) 3.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 2. Site Preparation The following steps must be completed before installing the system hardware. If the steps are not already completed refer to each individual section for details. 1. At the local site, install and test Primary Shelf and Expansion Shelves. Refer to Link WTS – Link 3000 MCU: Installation (72-0059-01) for information. 2. At the remote site: 2.
SpectraLink Corporation 2.2 T1 Remote Module Installation Link WTS – Link 3000 MCU T1 Configuration Requirements T1 circuits will connect expansion shelves directly to the System Controller shelf via the SpectraLink provided Intershelf Junction Panel. The Intershelf Junction Panel is always co-located with the system controller shelf. The following configuration requirements apply to the T1 lines connecting the Link 3000 MCU local and remote shelves.
SpectraLink Corporation 2.3 T1 Remote Module Installation Link WTS – Link 3000 MCU Check Components The following items should be at the installation site. Link 3000 MCU Expansion Shelves – (MCS300) – the number of shelves varies depending on the size of the system. Grounding Strap – (in the Link WTS Administration Kit, MKA320) – to protect cards from electrostatic discharge. Expansion Shelf Controller Card – (CSC300) - one card for each Expansion Shelf. This card is installed in Slot 2.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 3. Install T1 Remote Module at Local Site Before installing the hardware at the remote site, the Primary shelf at the local site must have a T1 Remote Module (CRC301) installed. Install one Remote Module for each remote shelf to be installed. Slide the Remote Module into slot 1 or slot 3-12 of any shelf, until the card clicks into place. Tighten the screws at the top and bottom of the card to secure it.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Network Clocked T1 Facilities If the T1 facilities are Network Clocked, one T1 Remote Module must be designated as the Master Clock Source. Connect the Sync IN port on this T1 Remote Module to AUX port A on the Intershelf Junction Panel. Note, this shelf must also be designated as the Master Clock in the system configuration.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU CRC-301 TIMING MASTER IN To AUX Port on Intershelf Junction Panel for Net Clocked T1 SYNC OUT ALARM 1 2 3 4 5 A SYSTEM CONTROLLER RJ45 to Intershelf Junction Panel B SC/A EXPANSION SHELF CONTROLLER SC/B LOS LIKOK DS1 A LOS LIKOK T1 connection Module 3-7 on remote DS1 B T1 connection Module 8-12 on remote Part Number: 72-0059-06-E.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 4. Install System at Remote Site 4.1 Survey Site Check the site to be sure pre-installation work has been completed correctly. This includes: • Location chosen for the shelves is adequate. • Rack (if rack mounted) is properly secured or backboard (if wall mounted) is properly prepared. • Power is available. • Wiring to Base Station locations has been pulled and correctly terminated.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Do not install cards until power is connected. 4.3 Connect Power to Shelves SpectraLink recommends that a licensed electrician install the –48V DC power supply and connect power to the shelves. See Link WTS – Link 3000 MCU: Installation, Connect Power to Shelves, for more information. 4.4 Install Cards The shelf diagram below shows a fully loaded Expansion Shelf.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU T1 Remote Expansion Shelf Controller Slot 2 Module Interface Modules Slots 3-12 RS-232 CRC-301 DISABLE DISABLE DISABLE DISABLE DISABLE NORMAL NORMAL DISABLE DISABLE DISABLE DISABLE DISABLE NORMAL NORMAL NORMAL TIMING MASTER NORMAL IN SC/A (RJ45) SC/B (RJ45) NORMAL NORMAL NORMAL NORMAL SYNC OUT ALARM 1 2 3 4 5 ALARM 1 2 3 4 5 CONN B ALARM 1 2 3 4 5 ALARM 1 2 3 4 5 ALARM 1 2 3 4 5 ALARM 1 2 3 4 5
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU The following diagram shows the T1 Remote Module connections at the REMOTE site.
SpectraLink Corporation 4.7 T1 Remote Module Installation Link WTS – Link 3000 MCU Connect Demarc Block RJ-21 Cables to Interface Modules Connect the male RJ-21 connector from the appropriate demarcation block to the designated RJ-21 connector (A or B) on each Interface Module. Secure the cables using the keeper. Dress the cables by wire wrapping the cable at the rear of the shelf. Part Number: 72-0059-06-E.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 5. Configure Remote System Use the Operator’s Console to enter configuration information for the Remote Expansion Shelves. 5.1 Configure Remote Shelf 1. From the Operator’s Console, select F1, Supervisor State Display. 2. Use the arrow keys to highlight the number of the Remote Shelf to be added (220), and press Enter. 3. Select Remote Card Options. 4. Select Edit Remote Cabinet Configuration. The following screen displays.
SpectraLink Corporation 5.2 T1 Remote Module Installation Link WTS – Link 3000 MCU Master Clock Configuration If the T1 facilities are Network Clocked, one shelf must be designated as the Master Clock Source. 1. From the Operator’s Console, select F8, Configuration Display and Administration. The following screen displays. 2. Select Field 12. Master Clock Cabinet. 3. Enter the shelf number of the Master Clock shelf. 4. Select SAVE to save the information. 5.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 6. Site Certification The installer should not leave the site before contacting SpectraLink to perform remote install verification. Before leaving the location where the Primary Shelf is installed, the installer must complete the following items: From the Operator’s Console, copy the PCS.CFG file to diskette. From the Operator’s Console, select F1 (Supervisor State) then select Dump Config to PCS.CFG.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 7. Installation Forms This section contains the following forms: Base Station Locations Extension Assignments Site Preparation Checklist Customer Acceptance Form Copy these forms as needed. Be sure to maintain completed forms for future reference. Part Number: 72-0059-06-E.
SpectraLink Corporation 7.1 T1 Remote Module Installation Link WTS – Link 3000 MCU Base Station Location Form Shelf Number: ________ Interface Module: ________ Base Station # Location (e.g.: building, floor #, detailed description) Interface Module Circuit # Base Station 1 1 Base Station 2 2 Base Station 3 3 Base Station 4 4 Base Station 5 5 Base Station 6 6 Shelf Number: ________ Interface Module: ________ Base Station # Location (e.g.
SpectraLink Corporation 7.2 T1 Remote Module Installation Link WTS – Link 3000 MCU Extension Assignments Worksheet Shelf: _______ Interface Module: _______ Phone # Ext. # Name Interface Module Circuit # Phone 1 1 Phone 2 2 Phone 3 3 Phone 4 4 Phone 5 5 Phone 6 6 Phone 7 7 Phone 8 8 Phone 9 9 Phone 10 10 Phone 11 11 Phone 12 12 Phone 13 13 Phone 14 14 Phone 15 15 Phone 16 16 Part Number: 72-0059-06-E.
SpectraLink Corporation 7.3 T1 Remote Module Installation Link WTS – Link 3000 MCU Site Preparation Checklist If upon arrival the SpectraLink installer determines that the pre-installation work has not been completed correctly, the installer has two options: 1) the installer can leave the site and reschedule the installation when the action items have been completed or corrected, or 2) the installer can assist in preparing the site, and thus spend additional time installing the system.
SpectraLink Corporation 7.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Index Base station location form, 27 Master Clock, 24 Cards Network Clocked T1, 16 Configuration, 23, 24 Installing, 15, 19 Channel Service Unit, 13 Power, 19 Configuration Requirements Remote Installation Diagram, 9 T1, 13 CSU, 13 Remote Installation, Steps, 11 Remote Shelf Configuring, 23 Customer Acceptance Form, 30 Customer Support Hotline, 8 Remote Site Surveying, 18 Demarc block, 22 Diagram, Remote Installatio