User's Manual

Functional Description
43
SLES140A—March 2007 TVP5147M1PFP
2.11.30 Output Formatter 4 Register
Subaddress 36h
Default FFh
7 6 5 4 3 2 1 0
VS/VBLK [1:0] HS/CS [1:0] C_1 [1:0] C_0 [1:0]
VS/VBLK [1:0]: VS terminal function select
00 = VS/VBLK is logic 0 output.
01 = VS/VBLK is logic 1 output.
10 = VS/VBLK is vertical sync or vertical blank output corresponding to bit 1 (VS/VBLK) in the sync control
register at subaddress 32h (see Section 2.11.26).
11 = VS/VBLK is logic input (default).
HS/CS [1:0]: HS terminal function select
00 = HS/CS is logic 0 output.
01 = HS/CS is logic 1 output.
10 = HS/CS is horizontal sync or composite sync output corresponding to bit 0 (HS/CS) in the sync control
register at subaddress 32h (see Section 2.11.26).
11 = HS/CS is logic input (default).
C_1 [1:0]: C_1 terminal function select
00 = C_1 is logic 0 output.
01 = C_1 is logic 1 output.
10 = Reserved
11 = C_1 is logic input (default).
C_0 [1:0]: C_0 terminal function select
00 = C_0 is logic 0 output.
01 = C_0 is logic 1 output.
10 = Reserved
11 = C_0 is logic input (default).
C_x functions are only available in the 10-bit output mode.