Datasheet

Texcell-NetCom Co., Ltd. All rights reserved.
- 57
-
Subminiature Intermediate Power Relay CU
1. COIL
DATA (at 23)
Nominal
Voltage (VDC)
Pick-up
Voltage (VDC)
Drop-out
Voltage (VDC)
Max Allowable
Voltage (VDC)
Coil Current
(mA)( 10%)
Coil Resistance
(Ω)
Coil Power
(mW)
3 2.25 0.18 3.90 66.7 45 x (1±10%)
200
5 3.75 0.25 6.50 40.0 125 x (1±10%)
6 4.50 0.30 7.80 33.3 180 x (1±10%)
9 6.75 0.45 11.7 22.2 405 x (1±10%)
12 9.00 0.60 15.6 16.7 720 x (1±10%)
18 13.5 0.90 23.4 11.1 1620 x (1±10%)
24 18.0 1.20 31.2 8.33 2880 x (1±10%)
2. CONTACT
DATA
Standard High Capacity
Contact Arrangement 1 Form A
Contact Resistance 100mΩ max. (at 1A 24VDC)
Contact Material AgNi
Contact Ratings 5A 250VAC / 30VDC 7A 250VAC / 30VDC
Max. Switching Voltage 277VAC / 30VDC
Max. Switching Current 5A 10A
Max. Switching Power 1,385VA / 150W 2770VA / 300W
Life Expectancy
Electrical
100,000 operations (at 5A 250VAC)
200,000 operations (at 3A 250VAC)
100,000 operations (at 7A 250VAC)
30,000 operations (at 10A 250VAC)
Mechanical 5,000,000 operations
Features
● 10kV impulse withstand voltage
(Between coil and contacts)
● Highly efficient magnetic circuit for high sensitivity (File No.:E134581)
: 200mW
● 10A switching capability
● Extremely small footprint utilizing PCB area

Summary of content (4 pages)