Instructions
6
manual
• Choose another place for the
transmitters and/or the temperature
station
• Reduce the distance between the
transmitters and the temperature
station
•
Check if there is any source of
interference
No DCF reception
•
Time reception setting “ON”
• Choose another place for the
temperature station
• Manual time setting
•
Wait for attempted reception during
the night
Incorrect display
• Change batteries
WASTE DISPOSAL
This product has been manufactured using high-grade materials and
components which can be recycled and reused.
Never throw flat batteries and rechargeable batteries in household
waste.
As a consumer, you are legally required to take
them to your retail store or to appropriate collection
sites according to national or local regulations in
order to protect the environment.
The symbols for the heavy metals contained are:
Cd=cadmium, Hg=mercury, Pb=lead
This instrument is labelled in accordance with the
EU Waste Electrical and Electronic Equipment
Directive (WEEE).
Please do not dispose of this product with other
household waste. The user is obligated to take end-
of-life devices to a designated collection point for the
disposal of electrical and electronic equipment, in
order to ensure environmentally-compatible disposal.
SPECIFICATIONS:
Recommended operating temperature range :
5ºC to 40ºC / +41ºF to 104ºF
Measuring range:
Indoor temperature : -9.9ºC to +59.9ºC with 0.1°C resolution/
+14.2ºF to +139.8ºF with 0.2ºF resolution
(“OF.L” displayed if outside this range)
Outdoor temperature : -39.9ºC to +59.9ºC with 0.1°C resolution /
-39.8ºF to +139.8ºF with 0.2ºF resolution
(“OF.L” displayed if outside this range)
Dew point temperature : -9.9ºC to +59.9ºC with 0.1°C resolution /
14.2ºF to 139.8ºF with 0.2ºF resolution
(“OF.L” displayed if outside this range)
Pool temperature : 0ºC to +59.9ºC with 0.1°C resolution /
+32ºF to +139.8ºF with 0.2ºF resolution
(“OF.L” displayed if outside this range)
Indoor humidity range : 20% to 95% with 1% resolution (Display “-
-“ if temperature is OL.F; display “19%” if
< 20% and “96%” if > 95%)
Data checking intervals:
Indoor temperature : Every 16 seconds
Indoor humidity : Every 16 seconds
Outdoor temperature : Every 10 seconds
Transmission range:
Temperature transmitter : up to 100 meters (open space)
Pool sensor :
up to 100 meters in air (open space)
: up to 25 meters in water
Power consumption (Alkaline batteries recommended):
Temperature station : 2 x AAA, IEC LR3, 1.5V
Temperature transmitter : 2 x AAA, IEC LR3, 1.5V
Pool sensor : 2 x AA, IEC LR6, 1.5V
Battery life cycle:
Temperature station : approximately 12 months
Temperature transmitter : approximately 24 months
Pool sensor : approximately 24 months
Dimensions (L x W x H) :
Temperature station : 94.6 x 20 x 157mm
Temperature transmitter : 41 x 19 x 128mm
Pool sensor : Ø 110.4 x 134mm (W)
TFA Dostmann GmbH & Co. KG, Zum Ottersberg 12, D - 97877
Wertheim
No part of this manual may be reproduced without written consent of
TFA Dostmann. The technical data are correct at the time of going to
print and may change without prior notice.
DECLARATION OF CONFORMITY
Herewith we declare, that this wireless transmission device does
comply with the essentials requirements of R&TTE Directive
1999/5/EC.
A copy of the signed and dated Declaration of Conformity is available
on request via info@tfa-dostmann.de.
www.tfa-dostmann.de
11/13