Operation Manual

2726
KLIMA-MONITOR - Wireless Thermo-Hygrometer
KLIMA-MONITOR - Wireless Thermo-Hygrometer
Resolution temperature 0,1°C
Accuracy humidity ±5 % @ 20 … 90%
Resolution humidity 1 %
Indication LL.L / HH.H Temperature is outside measuring range
Range max. 100 m (free field)
Transmission frequency 433 MHz
Transmission time Transmitter transmitted every 60 seconds
Power consumption
Basic station 4 x 1,5 V AAA (batteries not included)
Transmitter 2 x 1,5 V AAA (batteries not included)
Basic station:
Dimensions 116 x 24 (64) x 116 mm
Weight 143 g (instrument only)
Transmitter:
Dimensions 45 x 20 x 110 mm
Weight 52 g (instrument only)
TFA Dostmann GmbH & Co.KG, Zum Ottersberg 12, D-97877 Wertheim.
No part of this manual may be reproduced without written consent of TFA Dostmann. The
technical data are correct at the time of going to print and may change without prior
notice.
The latest technical data and information about your product can be found by entering
your product number on our homepage.
EU-KONFORMITÄTSERKLÄRUNG
Herewith we declare, that this wireless transmission device does comply with the essentials
requirements of R&TTE Directive 1999/5/EC.
A copy of the signed and dated Declaration of Conformity is available on request via
info@tfa-dostmann.de.
www.tfa-dostmann.de 10/14
11.2 Calibration of the display of the temperature
Press the CHANNEL / + button until the arrow appears on the desired channel.
Press the ALARM / SET and the CHANNEL / + button at the same time for
5 seconds.
The temperature display will be flashing.
Press the CHANNEL / + or the MIN/MAX / – button to correct the tempera-
ture value.
Press the ALARM / SET button briefly, on the display appears the normal
measurement or press and hold the ALARM / SET button for 3 seconds to
confirm the set value.
12. Waste disposal
This product has been manufactured using high-grade materials and compo-
nents which can be recycled and reused.
Never dispose of empty batteries and rechargeable batteries in
household waste.
As a consumer, you are legally required to take them to your retail
store or to an appropriate collection site depending on national or
local regulations in order to protect the environment.
The symbols for the heavy metals contained are:
Cd=cadmium, Hg = mercury, Pb=lead
This instrument is labelled in accordance with the EU Waste Electri-
cal and Electronic Equipment Directive (WEEE).
Please do not dispose of this instrument in household waste. The
user is obligated to take end-of-life devices to a designated collec-
tion point for the disposal of electrical and electronic equipment,
in order to ensure environmentally-compatible disposal.
13. Specifications
Measuring range
Indoor temperature 0 °C… +60°C (+32 °F …+140 °F)
Outdoor temperature -40 °C… +60 °C (-40 °F …+140 °F)
Humidity 10 … 99%
Accuracy temperature ±1°C
TFA_No. 30.3054_Anleitung 27.10.2014 17:04 Uhr Seite 14