Manual
Programmable Thermostat type HWPRS 
IntroductionIntroductionIntroduction
This thermostat can replace any standard room thermostat, and is designed for use with gas or oil heating systems. If you 
wish to control electric heating note that the current rating is 3A resistive. 
The thermostat is battery-powered and designed for wall mounting, using the backplate supplied. The HWPRS provides a 
volt-free contact to switch any load up to 3A @ 230V 50Hz and can be positioned wherever you would normally fit a room 
thermostat. 
Set time and weekday:Set time and weekday:Set time and weekday:
Insert the batteries into the thermostat; make sure that the batteries are inserted with polarity as indicated in the battery 
compartment. Press and hold the select and set buttons for 3 seconds. The hour will flash—adjust with the up or down 
arrow button, confirm with select button. Adjust the minute and the weekday in the same way. Press the Set button to 
return to normal running mode. 
Function and wiring of the receiverFunction and wiring of the receiverFunction and wiring of the receiver
1. All wiring should be carried out by a skilled person. Disconnect power before wiring. Fit a 3 Amp fuse to the receiver 
supply. 
2. The default temperature display shows the current room temperature. Press the up button until the set temperature is 2 
degrees higher than the current room temperature. 
3. Wait for a few seconds. The animated flame symbol should be seen in the bottom left-hand corner of the display. 
4. The heating system should now be running. 
5. Press the down button on the transmitter to reduce the temperature below the current room temperature. Wait for a few 
seconds. The animated flame symbol should disappear, and the heating should switch off. 
6. If responses do not occur as expected during steps 1—4 above, press the reset button on the thermostat and repeat 
steps 1 – 4. 
Wiring information:Wiring information:Wiring information:
Using the crimp connectors and insulating boots provided, connect wiring to the receiver as shown below. For conven-
tional heating installations, connections will be required to terminals L, SL & Earth.  
L  Live In 
SL  Switched Live Output 
Earth  Earth Park 
Wiring:Wiring:Wiring: 
Push button functionPush button functionPush button function
 Key  Function 
  Increase setpoint temperature 
  Decrease setpoint temperature 
  Turn on backlight for 5 seconds. 
Activate / deactivate Frost Protection 
SET  Key for confirming and program setting 
SELECT  Key for program setting 
RESET  System reset 
111