User's Manual
COMTRAC RADIO
USER MAUAL
Business Entity Identifier
Business Identifier
DTC
Revision
9950-15900
3CU 04036 0026 PCZZA
108
0A
CONFIDENTIAL © Thales Canada, Transportation Solutions. All rights reserved. Passing on or copying of this document,
use or communication of its content in whole or in part is not permitted without prior written authorization.
Template : 83410477-DOC-CAN-EN
10 / 37
4. PHYSICAL INTERFACES – STANDALONE VARIANT
4.1 Console Ports
A console port is provided for each side. Side-A is interfaced through ADMIN-A, and the
side-B is interfaced through ADMIN-B.
The console interface uses a standard female DB9. The pin-outs are listed below.
When using a USB to serial adaptor, it is recommended to keep the serial cable portion
as short as possible.
DB-9 Female
Connector Pin Out
RS-232 Signal
1
Not Connected
2
RxD
3
TxD
4
DTR
5
Signal Ground
6
DSR
7
RTS
8
CTS
9
Not Connected
Console Port
Default Port Settings
Bits Per Second
115200
Data Bits
8
Parity
None
Stop Bits
1
Flow Control
None
4.2 Discrete IO Port
The discrete Input Output (IO) port, labelled AUX is currently not supported.