Installation Manual

THALES COMMUNICATIONS
OIM
AHV1600-SYSTEM
Page 119
July 16/09
(5) PERFORMANCE

Altitude: 5000 ft

Height accuracy: (
2 ft + 2% of the true height)
D. ENVIRONMENTAL CONDITIONS
DO160E Cat. [(B4)X]BBB[RG]XWFDFSZZAZ[ZC][HF]M[(A4G33)(A3J33)]XXAX
Environmental Condition DO160E
DO160E
section
Description of conducted test
Temperature and altitude 4 Category B4
Temperature variation 5 Category B
Humidity 6 Category B
Operational shocks and crash safety 7 Category B
Vibration 8 Category R curve G
Explosive atmosphere 9 Not required Category X
Waterproofness 10 Category W
Fluids susceptibility 11 Category F
Sand and dust 12 Category D
Fungus resistance 13 Category F
Salt Fog 14 Category S
Magnetic effect 15 Category Z
Power input 16
Category Z
TCF declares that the AHV1600 Transceiver is able to
withstand momentary power interruption up to 2ms (Test
condition 1 of table 16-3).
Voltage spike 17 Category A
Audio frequency conducted suscep-
tibility – power inputs
18 Category Z
Induced signal susceptibility 19 Category ZC
Radio frequency susceptibility (radi-
ated and conducted)
20
Category H for Conducted Susceptibility
Category F for Radiated Susceptibility
Emission of radio frequency energy 21 Category M
Lightning induced transient suscepti-
bility
22
Pin Injection Tests :
Equipment tested to
Category
(A4)
for power lines and
(A3)
for interconnecting lines.
Cable Bundle Tests :
Equipment tested to
Category
(G33)
for power lines and
(J33)
for interconnecting lines.
Lightning direct effects 23 Not required Category X
Icing 24 Not required Category X
Electrostatic discharge 25 Category A
Fire, Flammability 26 Not required Category X